Search arXivSearch

arXiv · 2411.13832

Smartphone tristimulus colorimetry for skin-tone analysis at common pulse oximetry anatomical sites

Abstract

Significance: Smartphones hold great potential in point-of-care settings due to their accessibility and computational capabilities. This is critical as clinicians increasingly seek to quantify skin-tone, a characteristic which has been shown to impact the accuracy of pulse oximetry readings, particularly for dark skin tones, and hence, disproportionately affect patient outcomes. Aim: This study presents a smartphone-based imaging technique for determining individual typology angle (ITA) and compares these results to those obtained using an industry-standard tristimulus colorimeter, particularly for the finger, a common site for pulse oximetry measurements. Approach: We employ a smartphone-based imaging method to extract ITA values from four volunteers with diverse skin-tones. The study provides recommendations for minimizing errors caused by ambient light scattering, which can affect skin-tone readings. Results: The smartphone-based ITA (SITA) measurements with camera flash disabled and minimal ambient lighting correlates well with the industry-standard colorimeter without the need for auxiliary adapters and complex calibration. The method presented enables wide-field ITA mapping for skin-tone quantification that is accessible to clinicians. Conclusions: Our findings demonstrate that smartphone-based imaging provides an effective alternative for assessing skin-tone in clinical settings. The reduced complexity of the approach presented makes it highly accessible to the clinical community and others interested in carrying out pulse oximetry across a diversity of skin-tones in a manner that standardizes skin-tone assessment.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Joshua A. Burrow, Rutendo Jakachira, Gannon Lemaster, Kimani C. Toussaint Jr. 2024-11-21. Smartphone tristimulus colorimetry for skin-tone analysis at common pulse oximetry anatomical sites. https://arxiv.org/abs/2411.13832

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Prediction of biological radiation effects based on ionization clusters (nanodosimetry)

This article reviews approaches that link the formation of ionization clusters in nanometric volumes to radiobiological effectiveness. The corresponding models were developed as the field of nanodosimetry developed. Some address early biological radiation effects, such as DNA damage, while most aim to predict cell survival or inactivation. The models also differ in the nanodosimetric quantities considered, with many based on the probability distribution of ionization cluster formation in a single target. Some models account for the synergistic effects of pairs of ionization clusters formed in different targets. Several models feature macroscopic aggregation frameworks based on particle fluence, which are proposed for use in radiotherapy treatment planning, particularly in ion-beam radiotherapy. The models are presented here using harmonized terminology and notation for nanodosimetric quantities. An extension of the conceptual framework of nanodosimetry is also discussed. This extension transitions from a target-centered description to a track-centered description. It also introduces nanodosimetry-based analogs of dosimetric concepts, such as dose and linear energy transfer. This paper traces and summarizes the historical development of nanodosimetry-based biological effect models and discusses conceptual aspects of the models to reveal their underlying assumptions and the extent to which they are mechanistic or merely elucidate correlations. Eventually, an attempt is made to identify the key open questions in this field that still need to be addressed.

physics.med-ph

Contextual Cellular Growth (ConCeG) of neural cells for realistic grey matter tissue generation for diffusion MRI simulations

Accurate interpretation of diffusion magnetic resonance imaging (dMRI) signals in grey matter (GM) remains challenging due to the complex, heterogeneous, and densely packed cellular environment. Numerical phantoms provide a controlled framework for investigating the relationship between microstructure and diffusion signals, yet existing approaches often lack the morphological realism and multi-cellular organisation required to faithfully represent GM tissue. In this work, we introduce Contextual Cellular Growth (ConCeG), a generative framework for creating individual cells or constructing dense, three-dimensional, multi-cellular GM substrates informed by real neuronal and glial morphologies. The method combines topological neuron synthesis with a spatially constrained growth network, allowing for the controlled generation of heterogeneous cellular environments with realistic intra- and extracellular compartments. Synthetic cells are generated using morphological and topological characteristics derived from biological reconstructions. We validate the framework through comparisons of structural features with real cellular data, demonstrating strong agreement in branch order, length, angle, and tortuosity distributions. Power spectrum analysis further shows that both intracellular compartments reproduce the spatial correlations observed in biological tissue. Together, these results show ConCeG provides a biologically grounded framework for generating grey matter substrates suitable for large scale diffusion MRI simulation.

physics.med-ph

Magnetic Field of Firing Neuron in Humans: Measurable by Quantum Sensing MRI?

Firing neurons generate action potentials that propagate along axons to transmit signals supporting cognitive functions. These electrical currents generate magnetic fields, yet direct detection of these neuronal magnetic fields by MRI remains elusive. This Mini Review investigates why this goal has been proven difficult to achieve and whether an emerging approach, quantum sensing MRI, can overcome the challenge.

physics.med-ph