Search arXivSearch

arXiv · 2411.18063

Mortality Prediction of Pulmonary Embolism Patients with Deep Learning and XGBoost

Abstract

Pulmonary Embolism (PE) is a serious cardiovascular condition that remains a leading cause of mortality and critical illness, underscoring the need for enhanced diagnostic strategies. Conventional clinical methods have limited success in predicting 30-day in-hospital mortality of PE patients. In this study, we present a new algorithm, called PEP-Net, for 30-day mortality prediction of PE patients based on the initial imaging data (CT) that opportunistically integrates a 3D Residual Network (3DResNet) with Extreme Gradient Boosting (XGBoost) algorithm with patient level binary labels without annotations of the emboli and its extent. Our proposed system offers a comprehensive prediction strategy by handling class imbalance problems, reducing overfitting via regularization, and reducing the prediction variance for more stable predictions. PEP-Net was tested in a cohort of 193 volumetric CT scans diagnosed with Acute PE, and it demonstrated a superior performance by significantly outperforming baseline models (76-78\%) with an accuracy of 94.5\% (+/-0.3) and 94.0\% (+/-0.7) when the input image is either lung region (Lung-ROI) or heart region (Cardiac-ROI). Our results advance PE prognostics by using only initial imaging data, setting a new benchmark in the field. While purely deep learning models have become the go-to for many medical classification (diagnostic) tasks, combined ResNet and XGBoost models herein outperform sole deep learning models due to a potential reason for having lack of enough data.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Yalcin Tur, Vedat Cicek, Tufan Cinar, Elif Keles, Bradlay D. Allen, Hatice Savas, Gorkem Durak, Alpay Medetalibeyoglu, Ulas Bagci. 2024-11-27. Mortality Prediction of Pulmonary Embolism Patients with Deep Learning and XGBoost. https://arxiv.org/abs/2411.18063

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Anatomy-Change-Aware Bidirectional Selective State-Space Memory for Clinically Deployed Thoracic Radiotherapy Auto-Contouring

We developed DAMM-Net++, a 2.5D architecture for thoracic OAR and target volume segmentation that addresses three persistent challenges in radiotherapy auto-contouring: inter-slice surface incoherence, systematic failure on small low-contrast targets, and the absence of per-case reliability signals. The central component is an anatomy-change-aware bidirectional selective state-space memory that models through-plane anatomical change and selectively propagates context along the axial slice sequence. A boundary-aware decoder sharpens near-surface predictions, and an uncertainty head provides calibrated per-voxel confidence for clinical triage. We evaluated 2,146 patients across four centers, an independent external cohort of 112 patients, and a multicenter reader study involving 17 radiation oncologists on 305 cases. The model achieves a mean Dice of 0.955 and HD95 of 3.78 mm, with the largest gains on low-contrast organs-at-risk (OARs) and target volumes where through-plane context is most critical. The uncertainty head is well-calibrated and supports case-level triage. In the reader study, AI assistance reduced contouring time by 75-80% across experience levels and raised junior-reader IoU from 0.861 to 0.925, matching the unedited model. External validation showed a modest internal-to-external drop (< 5%) with calibrated uncertainty transferring without recalibration. The complete deployment pipeline from DICOM ingestion to TPS-compatible RTSTRUCT export has been integrated into the clinical workflow at a partner hospital, where it is used to assist with contouring. These results suggest that anatomically motivated inter-slice memory, paired with uncertainty-guided review, offers a clinically viable path for thoracic auto-contouring.

eess.IV

A Controlled Evaluation of Quantum Correlation Refinement for Few-Shot Semantic Segmentation: Resource Cost and IBM Quantum Hardware Validation

PQCs are increasingly proposed as trainable components in classical ML pipelines, but rarely characterized alongside a controlled measurement of task-level benefit. We report such an evaluation, using few shot segmentation as testbed. We integrate a Quantum Correlation Refiner (QCR), a six-qubit variational circuit with amplitude embedding and a gated residual connection into a classical correlation-based architecture, under the four fold PASCAL 5i protocol, three seeds per fold, against an unrefined baseline and a matched MLP refiner. Across 12 fold-seed comparisons, QCR changes mIoU by only +0.0001 (t(11)=0.10, p=0.92, dz=0.03); the MLP control and an expanded Pauli-measurement variant show similarly no improvement. QCR adds just 473 parameters but roughly doubles per epoch training time. A trained circuit on IBM hardware (18 patches) agrees closely with the noiseless simulator (r=0.954, MAE=0.101), a fidelity check, not an accuracy gain. The module is functional, trainable, and hardware deployable, yet shows no task-level advantage over a matched classical alternative under this regime, a template for evaluating quantum components jointly via matched controls, repeated seeds, resource measurement, and hardware validation, rather than any one alone.

eess.IV

Scalable SSIM Estimation from PSNR for Per-Title and Context-Adaptive Encoding Workflows

Modern streaming pipelines run hundreds of candidate encodes per asset to support per-title encoding, shot-based optimization, and context-adaptive ABR ladder construction. These techniques have moved perceptual quality metrics into the critical path: SSIM and VMAF now guide encoding decisions rather than passively monitor them. We measure that SSIM evaluation accounts for 7-35% of x264 encode time at production speed presets, with the cost ratio rising as encoders run faster. We propose ApproxSSIMate, a low-complexity method for estimating SSIM from PSNR combined with reference-sequence statistics computed once per sequence and reused across every candidate encode. This decouples quality estimation from the encode-decode-compare loop, enabling perceptual quality feedback in live encoding and amortizing quality measurement across candidate encodes in per-title workflows. We validate the approach across H.264/AVC, H.265/HEVC, and AV1 on the Objective-1-fast dataset and release the implementation as free and open-source software.

eess.IV