Abstract

In MRI-guided laser interstitial thermotherapy (MRgLITT), a signal void sometimes appears at the heating center of the measured temperature map. In neurosurgical MRgLITT treatments, cerebrospinal fluid pulsation (CSF), which may lead to temperature artifacts, also needs to be carefully managed. We find that signal loss in MR magnitude images can be one distinct contributor to the temperature imaging signal void. Therefore, this study aims to investigate this finding and more importantly. Also, this study intends to improve measurement accuracy by correcting CSF-induced temperature errors and employing a more reliable phase unwrapping algorithm. A gradient echo sequence with certain TE values for temperature imaging is used to quantify T2* variations during MRgLITT and to investigate the development of signal voids throughout the treatment. Informed by these findings, a multi-echo GRE sequence with appropriate TE coverage is employed. A multi-echo-based correction algorithm is developed to address the signal loss-induced temperature errors. A new phase unwrapping method and a new CSF pulsation correction approach are developed for multi-echo signal processing. The temperature imaging method is evaluated by gel phantom, ex-vivo, and in-vivo LITT heating experiments. T2* shortening during heating can be one important cause of the temperate imaging signal voids and this demands the multi-echo acquisition with varied TE values. The proposed multi-echo-based method can effectively correct signal loss-induced temperature errors and raise temperature estimation precision. The multi-echo thermometry in the in-vivo experiments shows smoother hotspot boundaries, fewer artifacts, and improved thermometry reliability. In the in-vivo experiments, the ablation areas estimated from the multi-echo thermometry also show satisfactory agreement with those determined from post-ablation MR imaging.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ziyi Pan, Yuancheng Jiang, Wenbo Lv, Sisi Li, Meng Han, Yawei Kuang, Hao Sun, Xiu Wang, Jianjun Bai, Wenbo Liu, Guangzhi Wang, Hua Guo. 2024-11-29. Artifact Correction in Magnetic Resonance Temperature Imaging for Laser Interstitial Thermotherapy with Multi-echo Acquisitions. https://arxiv.org/abs/2411.19559

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Prediction of biological radiation effects based on ionization clusters (nanodosimetry)

This article reviews approaches that link the formation of ionization clusters in nanometric volumes to radiobiological effectiveness. The corresponding models were developed as the field of nanodosimetry developed. Some address early biological radiation effects, such as DNA damage, while most aim to predict cell survival or inactivation. The models also differ in the nanodosimetric quantities considered, with many based on the probability distribution of ionization cluster formation in a single target. Some models account for the synergistic effects of pairs of ionization clusters formed in different targets. Several models feature macroscopic aggregation frameworks based on particle fluence, which are proposed for use in radiotherapy treatment planning, particularly in ion-beam radiotherapy. The models are presented here using harmonized terminology and notation for nanodosimetric quantities. An extension of the conceptual framework of nanodosimetry is also discussed. This extension transitions from a target-centered description to a track-centered description. It also introduces nanodosimetry-based analogs of dosimetric concepts, such as dose and linear energy transfer. This paper traces and summarizes the historical development of nanodosimetry-based biological effect models and discusses conceptual aspects of the models to reveal their underlying assumptions and the extent to which they are mechanistic or merely elucidate correlations. Eventually, an attempt is made to identify the key open questions in this field that still need to be addressed.

physics.med-ph

Contextual Cellular Growth (ConCeG) of neural cells for realistic grey matter tissue generation for diffusion MRI simulations

Accurate interpretation of diffusion magnetic resonance imaging (dMRI) signals in grey matter (GM) remains challenging due to the complex, heterogeneous, and densely packed cellular environment. Numerical phantoms provide a controlled framework for investigating the relationship between microstructure and diffusion signals, yet existing approaches often lack the morphological realism and multi-cellular organisation required to faithfully represent GM tissue. In this work, we introduce Contextual Cellular Growth (ConCeG), a generative framework for creating individual cells or constructing dense, three-dimensional, multi-cellular GM substrates informed by real neuronal and glial morphologies. The method combines topological neuron synthesis with a spatially constrained growth network, allowing for the controlled generation of heterogeneous cellular environments with realistic intra- and extracellular compartments. Synthetic cells are generated using morphological and topological characteristics derived from biological reconstructions. We validate the framework through comparisons of structural features with real cellular data, demonstrating strong agreement in branch order, length, angle, and tortuosity distributions. Power spectrum analysis further shows that both intracellular compartments reproduce the spatial correlations observed in biological tissue. Together, these results show ConCeG provides a biologically grounded framework for generating grey matter substrates suitable for large scale diffusion MRI simulation.

physics.med-ph

Magnetic Field of Firing Neuron in Humans: Measurable by Quantum Sensing MRI?

Firing neurons generate action potentials that propagate along axons to transmit signals supporting cognitive functions. These electrical currents generate magnetic fields, yet direct detection of these neuronal magnetic fields by MRI remains elusive. This Mini Review investigates why this goal has been proven difficult to achieve and whether an emerging approach, quantum sensing MRI, can overcome the challenge.

physics.med-ph