Bulk-Surface Event Discrimination in Point Contact Germanium Detectors at Near-Threshold Energies with Shape-Matching Pulse-Shape Methods

Abstract

The p-type point-contact germanium (pPCGe) detectors have been widely adopted in searches for low energy physics events such as neutrinos and dark matter. This is due to their enhanced capabilities of background rejection, sensitivity at energies as low as the sub-keV range and particularly fine energy resolution. Nonetheless, the pPCGe is subject to irregular behaviour caused by surface effects for events near the passivated surface. These surface events can, in general, be distinguished from events that occur in the germanium crystal bulk by its slower pulse rise time. Unfortunately, the rise-time spectra of bulk and surface events starts to convolve with each other at sub-keV energies. In this work, we propose a novel method based on cross-correlation shape-matching combined with a low-pass filter to constrain the initial parameter estimates of the signal pulse. This improvement at the lowest level leads to a 50% reduction in computation time and refinements in the rise-time resolution, which will, in the end, enhance the overall analysis. To evaluate the performance of the method, we simulate artificial pulses that resembles bulk and surface pulses by using a programmable pulse generator module (pulser). The pulser-generated pulses are then used to examine the pulse behaviours at near-threshold energies, suggesting a roughly 70% background-leakage reduction in the bulk spectrum. Finally, the method is tested on data collected from the TEXONO experiment, where the results are consistent with our observations in pulser and demonstrated the possibility of lowering the analysis threshold by at least 10eV.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jia-Shian Wang, Manoj Kumar Singh, Hau-Bin Li, Henry Tsz-King Wong. 2025-03-25. Bulk-Surface Event Discrimination in Point Contact Germanium Detectors at Near-Threshold Energies with Shape-Matching Pulse-Shape Methods. https://doi.org/10.1140/epjc%2Fs10052-025-14051-x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.