Search arXivSearch

arXiv · 2412.02413

High-Quality Passive Acoustic Mapping with the Cross-Correlated Angular Spectrum Method

Abstract

While passive acoustic mapping (PAM) has been advanced for monitoring acoustic cavitation activity in focused ultrasound (FUS) therapy, achieving both real-time and high-quality imaging capabilities is still challenging. The angular spectrum (AS) method presents the most efficient algorithm for PAM, but it suffers from artifacts and low resolution due to the diffraction pattern of the imaging array. Data-adaptive beamformers suppress artifacts well, but their overwhelming computational complexity, more than two orders of magnitude higher than the classical time exposure acoustic (TEA) method, hinders their application in real-time. In this work, we introduce the cross-correlated AS method to address the challenge. This method is based on cross-correlating the AS back-propagated wave fields, in the frequency domain, measured by different apodized sub-apertures of the transducer array to provide the normalized correlation coefficient (NCC) matrix for artifacts suppression. We observed that the spatial pattern of NCC matrix is variable which can be utilized by the triple apodization with cross-correlation (TAX) with AS scheme, namely the AS-TAX method, for optimal artifacts suppression outcomes. Both the phantom and mouse tumor experiments showed that: 1) the AS-TAX method has comparable image quality as the data-adaptive beamformers, reducing the energy spread area by 34.8-66.6% and improving image signal-to-noise ratio by 10.7-14.5 dB compared to TEA; 2) it reduces the computational complexity by two orders of magnitude compared to TEA allowing millisecond-level image reconstruction speed with a parallel implementation; 3) it can well map microbubble cavitation activity of different status (stable or inertial). The AS-TAX method represents a real-time approach to monitor cavitation-based FUS therapy with high image quality.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Yi Zeng, Hui Zhu, Jinwei Li, Jianfeng Li, Fei Li, Shukuan Lu, Xiran Cai. 2024-12-03. High-Quality Passive Acoustic Mapping with the Cross-Correlated Angular Spectrum Method. https://arxiv.org/abs/2412.02413

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Prediction of biological radiation effects based on ionization clusters (nanodosimetry)

This article reviews approaches that link the formation of ionization clusters in nanometric volumes to radiobiological effectiveness. The corresponding models were developed as the field of nanodosimetry developed. Some address early biological radiation effects, such as DNA damage, while most aim to predict cell survival or inactivation. The models also differ in the nanodosimetric quantities considered, with many based on the probability distribution of ionization cluster formation in a single target. Some models account for the synergistic effects of pairs of ionization clusters formed in different targets. Several models feature macroscopic aggregation frameworks based on particle fluence, which are proposed for use in radiotherapy treatment planning, particularly in ion-beam radiotherapy. The models are presented here using harmonized terminology and notation for nanodosimetric quantities. An extension of the conceptual framework of nanodosimetry is also discussed. This extension transitions from a target-centered description to a track-centered description. It also introduces nanodosimetry-based analogs of dosimetric concepts, such as dose and linear energy transfer. This paper traces and summarizes the historical development of nanodosimetry-based biological effect models and discusses conceptual aspects of the models to reveal their underlying assumptions and the extent to which they are mechanistic or merely elucidate correlations. Eventually, an attempt is made to identify the key open questions in this field that still need to be addressed.

physics.med-ph

Contextual Cellular Growth (ConCeG) of neural cells for realistic grey matter tissue generation for diffusion MRI simulations

Accurate interpretation of diffusion magnetic resonance imaging (dMRI) signals in grey matter (GM) remains challenging due to the complex, heterogeneous, and densely packed cellular environment. Numerical phantoms provide a controlled framework for investigating the relationship between microstructure and diffusion signals, yet existing approaches often lack the morphological realism and multi-cellular organisation required to faithfully represent GM tissue. In this work, we introduce Contextual Cellular Growth (ConCeG), a generative framework for creating individual cells or constructing dense, three-dimensional, multi-cellular GM substrates informed by real neuronal and glial morphologies. The method combines topological neuron synthesis with a spatially constrained growth network, allowing for the controlled generation of heterogeneous cellular environments with realistic intra- and extracellular compartments. Synthetic cells are generated using morphological and topological characteristics derived from biological reconstructions. We validate the framework through comparisons of structural features with real cellular data, demonstrating strong agreement in branch order, length, angle, and tortuosity distributions. Power spectrum analysis further shows that both intracellular compartments reproduce the spatial correlations observed in biological tissue. Together, these results show ConCeG provides a biologically grounded framework for generating grey matter substrates suitable for large scale diffusion MRI simulation.

physics.med-ph

Magnetic Field of Firing Neuron in Humans: Measurable by Quantum Sensing MRI?

Firing neurons generate action potentials that propagate along axons to transmit signals supporting cognitive functions. These electrical currents generate magnetic fields, yet direct detection of these neuronal magnetic fields by MRI remains elusive. This Mini Review investigates why this goal has been proven difficult to achieve and whether an emerging approach, quantum sensing MRI, can overcome the challenge.

physics.med-ph