Search arXivSearch

arXiv · 2412.10154

A Clinical Tuning Framework for Continuous Kinematic and Impedance Control of a Powered Knee-Ankle Prosthesis

Abstract

Configuring a prosthetic leg is an integral part of the fitting process, but the personalization of a multi-modal powered knee-ankle prosthesis is often too complex to realize in a clinical environment. This paper develops both the technical means to individualize a hybrid kinematic-impedance controller for variable-incline walking and sit-stand transitions, and an intuitive Clinical Tuning Interface (CTI) that allows prosthetists to directly modify the controller behavior. Utilizing an established method for predicting kinematic gait individuality alongside a new parallel approach for kinetic individuality, we personalize continuous-phase/task models of joint impedance (during stance) and kinematics (during swing) using tuned characteristics exclusively from level-ground walking. To take advantage of this method, we developed a CTI that translates common clinical tuning parameters into model adjustments for the walking and sit-stand controllers. We then conducted a case study where a prosthetist iteratively tuned the powered prosthesis to an above-knee amputee participant in a simulated clinical session involving sit-stand transitions and level walking, from which incline/decline walking features were automatically calibrated. The prosthetist fully tuned the multi-activity prosthesis controller in under 20 min. Each iteration of tuning (i.e., observation, parameter adjustment, and model reprocessing) took 2 min on average for walking and 1 min on average for sit-stand. The tuned behavior changes were appropriately manifested in the commanded prosthesis torques, both at the manually tuned tasks and automatically tuned tasks (inclines). This paper introduces a clinical tuning interface that simplifies the tuning process for multimodal robotic prosthetic legs, reducing the time required from several hours to just 20 min thus improving clinical feasibility.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Emma Reznick, T. Kevin Best, Robert Gregg. 2025-05-11. A Clinical Tuning Framework for Continuous Kinematic and Impedance Control of a Powered Knee-Ankle Prosthesis. https://doi.org/10.1109/jtehm.2025.3567578

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

J-PARSE: Jacobian-based Projection Algorithm for Resolving Singularities Effectively in Inverse Kinematic Control of Serial Manipulators

J-PARSE is an algorithm for smooth first-order inverse kinematic control of a serial manipulator near kinematic singularities. The commanded end-effector velocity is interpreted component-wise, according to the available mobility in each dimension of the task space. First, a substitute ''Safety'' Jacobian matrix is created, keeping the aspect ratio of the manipulability ellipsoid above a threshold value. The desired velocity is then projected onto non-singular and singular directions, and the latter projection scaled down by a factor informed by the altered mobility. A right-inverse of the non-singular Safety Jacobian is applied to the modified command. In the absence of joint limits and collisions, this ensures safe transition into and out of low-mobility configurations, guaranteeing locally stable reaching behavior towards target poses within, on the boundary of, and outside the workspace. The behavior is further guaranteed to be locally asymptotically stable if the starting and target configurations are not exactly singular, even if they are nearly singular. Velocity control with J-PARSE is benchmarked against approaches from the literature, illustrating its use of a single tuning parameter to simultaneously achieve high reaching accuracy and stable behavior. Applications in teleoperation, servoing, and learning are demonstrated. Videos and code are available at https://jparse-manip.github.io/.

cs.RO

Spatiotemporal Calibration of Doppler Velocity Logs for Underwater Robots

The calibration of extrinsic parameters and clock offsets between sensors for high-accuracy performance in underwater SLAM systems remains insufficiently explored. Existing methods for Doppler Velocity Log (DVL) calibration are either constrained to specific sensor configurations or rely on oversimplified assumptions, and none jointly estimate translational extrinsics and time offsets. We propose a Unified Iterative Calibration (UIC) framework for general DVL sensor setups, formulated as a Maximum A Posteriori (MAP) estimation with a Gaussian Process (GP) motion prior for high-fidelity motion interpolation. UIC alternates between efficient GP-based motion state updates and gradient-based calibration variable updates, supported by a provably statistically consistent sequential initialization scheme. The proposed UIC can be applied to IMU, cameras and other modalities as co-sensors. We release an open-source DVL-camera calibration toolbox. Beyond underwater applications, several aspects of UIC-such as the integration of GP priors for MAP-based calibration and the design of provably reliable initialization procedures-are broadly applicable to other multi-sensor calibration problems. Finally, simulations and real-world tests validate our approach.

cs.RO

HazardArena: Evaluating Semantic Safety in Vision-Language-Action Models

Vision-Language-Action (VLA) models inherit rich world knowledge from vision-language backbones and acquire executable skills via action demonstrations. However, existing evaluations largely focus on action execution success, leaving action policies loosely coupled with visual-linguistic semantics. This decoupling exposes a systematic vulnerability whereby correct action execution may induce unsafe outcomes under semantic risk. To expose this vulnerability, we introduce HazardArena, a benchmark designed to evaluate semantic safety in VLAs under controlled yet risk-bearing contexts. HazardArena is constructed from safe/unsafe twin scenarios that share matched objects, layouts, and action requirements, differing only in the semantic context that determines whether an action is unsafe. We find that VLA models trained exclusively on safe scenarios often fail to behave safely when evaluated in their corresponding unsafe counterparts. HazardArena includes over 2,000 assets and 40 risk-sensitive tasks spanning 7 real-world risk categories grounded in established robotic safety standards. To mitigate this vulnerability, we propose a training-free Safety Option Layer that constrains action execution using semantic attributes or a vision-language judge, substantially reducing unsafe behaviors with minimal impact on task performance. We hope that HazardArena highlights the need to rethink how semantic safety is evaluated and enforced in VLAs as they scale toward real-world deployment. Code released at https://github.com/HazardArena-Team/HazardArena ; updated code availability information.

cs.RO