Search arXivSearch

arXiv · 2501.00875

A metamaterial telescope at millimetre wavelengths

Abstract

In this paper we present a novel telescope composed exclusively of thin, flat optical elements, each being a hot-pressed multi-layered structure combining the properties of a lens, its anti-reflection coating and frequency selection or filtering. We discuss the design process, from fundamental physical metamaterial properties of the single periodic cell structure to the lens concept, which constitutes the building block of the telescope design, and the iterative process that is part of the lens optimization. We provide the results of a laboratory test campaign for different telescope designs based on three-lens arrangements. Beam cuts and focus measurements both on- and off-axis are compared with models showing good agreement. We conclude that a broad-band mm-wave complete telescope system consisting entirely of metamaterial flat lenses has been built and tested, showing comparable performance with conventional state-of-the-art refractive telescopes in the same wavelength region. This new broadband design, highly efficient at frequencies between 90 and 190 GHz, offers multiple advantages. These include a $> 80\%$ weight reduction, reduced issues tied to coating-survivability at cryogenic temperatures caused by differential contraction exacerbated by non-flat surfaces, as well as a reduction in the overall number of components and mechanical mounts.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Giorgio Savini, Peter Hargrave, Peter A. R. Ade, Alexey Shitvov, Rashmi Sudiwala, Giampaolo Pisano, Carole Tucker, Jin Zhang. 2025-01-01. A metamaterial telescope at millimetre wavelengths. https://arxiv.org/abs/2501.00875

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Performance characterization of a new Structural and Thermal Architecture for a future spaceborne Closed-Cycle Dilution Refrigerator

A Structural and Thermal Model (STM) has been developed to support the new spaceborne Closed-Cycle Dilution Refrigerator (CCDR), which aims to provide continuous cooling at 100~mK for long-duration astrophysical missions. The STM is based on a hexapod architecture that ensures both thermal decoupling and mechanical robustness during launch. In this paper, we present the characterization of its thermal and mechanical performances. A dedicated experimental setup was used to investigate the thermal behavior of the STM across a broad temperature range. The study reveals limitations of the collar design, with incomplete power interception from thermal boundary resistances and vibration test failure traced to defective strut gluing. These results guide the next STM iteration with optimized collar and strut assembly for reliable CCDR operation in space.

astro-ph.IM

The Simons Observatory: Development of a Pipeline to Detect Rapid Transients in Time-Ordered Data

We introduce a method for detecting astrophysical transients evolving on timescales of milliseconds to minutes using cosmic microwave background (CMB) survey telescopes. While previous transient searches in CMB data operate in map space, our pipeline directly processes the raw time-ordered data, enabling sensitivity to fast, dynamic signals. We integrate our detection approach into the Simons Observatory time-domain pipeline and assess the performance by injecting symmetric, stellar flare-like light curves into simulated observations. For events flaring with a timescale of 0.5 s, the pipeline detects $\gtrsim90$ % of events at flux densities of 800, 1150, 1650, and 4250\,mJy when measured in the 93, 145, 225, and 280 GHz bands respectively. At a fixed peak flux density, the pipeline more readily detects longer flares. The limiting flux density for 90 % completeness is four times lower for a $\ge5$ s flare than for a 0.5 s flare, while the flux density limits for $\gtrsim50$ % detection efficiency are comparable to the rms noise of the time-ordered data. We are able to determine the position of detected events in each observing band, with a positional uncertainty at the detection threshold comparable to the telescope resolution at that band. These results demonstrate the readiness of this pipeline for incorporation into upcoming Simons Observatory data analyses.

astro-ph.IM

Thermal conductivity of various CFRPs from 100 mK to 20 K

Carbon-fiber-reinforced polymers (CFRPs) are some of the most useful materials for building spacecraft and aerospace tools. They are especially valuable for systems that work at extremely cold (cryogenic) temperatures because they are strong, lightweight, and don't transfer heat easily. In this study, researchers measured how well heat moves through several different types of carbon fiber samples, specifically T300, T700, HS40, M55J, and IMA, at different fiber layouts and densities. These measurements were taken at ultra-cold temperatures ranging from 100 mK to 20 K. The team used a newly developed analysis method to calculate the thermal conductivity for each sample. Finally, they shared how each material behaved at different temperatures and compared their findings to previous research.

astro-ph.IM