Search arXivSearch

arXiv · 2501.05592

Development of SQUID Array Amplifiers for the LiteBIRD CMB Satellite

Abstract

LiteBIRD is an upcoming JAXA-led mission that aims to measure primordial gravitational waves in the B-mode polarization of the cosmic microwave background. It is set to launch in 2032. The LiteBIRD detector array consists of around 5000 TES detectors which are read out using digital frequency multiplexing over a bandwidth of 1-6 MHz. The multiplexing factor ranges from 58x to 68x. We are presently developing single-stage SQUID array amplifiers for LiteBIRD readout. Due to the reduced complexity and cost, and greater heritage from ground-based experiments such as the South Pole Telescope and Simons Array, single-stage SQUID array amplification is preferable for the first-stage amplification, as long as it can meet the requirements. The LiteBIRD single-stage SQUID Array is required to have high transimpedance amplification while maintaining a low input inductance and low dynamic resistance. In addition, the input-referred current noise must be very low, and the power dissipation must remain below about 100 nW. These requirements have non-trivial interactions. To maximize performance within these requirements we have performed lumped-element SQUID simulation. We find that by optimizing SQUID internal damping elements and inductive loading, good single-stage SQUID array performance can be obtained for LiteBIRD, including significant engineering margin.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S. T. P. Boyd, Tijmen de Haan. 2025-01-09. Development of SQUID Array Amplifiers for the LiteBIRD CMB Satellite. https://arxiv.org/abs/2501.05592

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det

Characterization of immersed SiPM arrays in liquid scintillator between room temperature and $-30\,^{\circ}\mathrm{C}$

Liquid scintillator detectors instrumented with distributed silicon photomultiplier (SiPM) arrays can be used in compact, topology-sensitive, and low-background experiments, but the temperature dependence of SiPMs immersed directly in the scintillation medium has not been widely characterized. We report the operation of a 125-liter linear-alkylbenzene-based liquid scintillator detector read out by 125 SiPM channels immersed in the active volume, over the range from room temperature to $-30\,^{\circ}\mathrm{C}$. The detector response was measured with cosmic-ray muons, including stopping muons followed by their Michel-electron decay. Cooling from $+15\,^{\circ}\mathrm{C}$ to $-30\,^{\circ}\mathrm{C}$ reduced the SiPM dark-count rate by a factor of 13.5, increased the single-photoelectron response by 49.1%, and increased the cosmic-ray muon light yield by 16.7%. The improved photoelectron separation and baseline stability at low temperature enabled a selection of stopping-muon events, from which the effective muon lifetime was measured to be $1959\pm132\,\mathrm{ns}$, consistent with the value expected for a hydrocarbon scintillator once $μ^{-}$ capture on carbon is taken into account.

physics.ins-det