LUCAS: A Low-Power Ultra-Low Jitter Compact ASIC for SiPM Targetting ToF-CT

Abstract

We present LUCAS (Low power Ultra-low jitter Compact ASIC for SiPM), an analog front-end for Silicon Photomultipliers (SiPM) targeting fast timing detectors in Time-of-Flight Computed Tomography (ToF-CT). LUCAS features a very low input impedance preamplifier followed by a voltage comparator. It is designed in TSMC 65 nm low-power CMOS technology with a power supply of 1.2 V. Our first 8-channel prototype has been sent to fabrication and will be received in August 2023. Post-layout simulations predict less than 40 ps FWHM SPTR jitter and an approximate power consumption of 3.2 mW per channel. The front end is suitable for applications with rigorous jitter requirements and high event rates, thanks to its 3.9 GHz unity-gain bandwidth. The front-end compact form factor will facilitate its incorporation into systems demanding high channel densities.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Seyed Arash Katourani. 2025-01-09. LUCAS: A Low-Power Ultra-Low Jitter Compact ASIC for SiPM Targetting ToF-CT. https://arxiv.org/abs/2501.07595

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det