Search arXivSearch

arXiv · 2501.08787

Calibration-free Rydberg Atomic Receiver for Sub-MHz Wireless Communications and Sensing

Abstract

The exploitation of sub-MHz (\textless 1 MHz) can be beneficial for a plethora of applications like underwater vehicular communication, subsurface exploration, low-frequency navigation etc. The traditional electrical receivers in this band are either hundreds of meters long or, when miniaturized, inefficient and bandwidth-limited, making them inapplicable for practical underwater implementations. Such obstacles can be circumvented by the emerging Rydberg atomic receiving technology, which is capable of detecting fields from DC up to the terahertz regime with compact structure. Against this background, we propose a method to detect sub-MHz electric fields without further calibration. Specifically, a physics-based model of the combined DC and AC-Stark response is established. Based on the model, we modulate the DC-Stark spectrum with the received signal and extract its amplitude by fitting the cycle-averaged, symmetric Stark-split peaks. Then we map this swing directly to the intrinsic atomic polarizability. By such operations, the proposed method can remove the dependence on electrode spacing or field-amplitude references. For performance evaluation, six-level Lindblad simulations and experiments are conducted at a low-frequency field of 30 kHz demonstrate a minimum detectable field of 5.3 \text{mV}/\text{cm}, with stable readout across practical optical-power variations. The approach manages to expand operating range of Rydberg atomic receivers below 1 MHz, and enables compact, calibration-free quantum front ends for underwater and subsurface receivers.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Minze Chen, Tianqi Mao, Wei Xiao, Zhonghuai Wu, Dapeng Li, Mingyao Cui, Qunsong Zeng, Dezhi Zheng, Kaibin Huang, Zhaocheng Wang. 2025-10-23. Calibration-free Rydberg Atomic Receiver for Sub-MHz Wireless Communications and Sensing. https://arxiv.org/abs/2501.08787

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

TCAD + Allpi$\text{x}^2$ Simulation study of MALTA2, a Depleted Monolithic Active Pixel Sensor for future tracking

In this work, a hybrid simulation framework combining TCAD and Allpi$\text{x}^2$ is presented to investigate the sensor properties of MALTA2, a depleted monolithic active pixel sensor designed for future tracking. The study starts from 3D modeling and transient simulations in TCAD, with generic doping profiles and simple well structures. The resulting doping profiles and electric field are extracted and fed into Allpi$\text{x}^2$ for high-statistics Monte Carlo simulations in both DUT-only and full-telescope mode. Simulations reveal a strong dependence of sensor performance, specifically the detection efficiency and cluster size, on the doping concentration of the N-type blanket at the sensor surface. The doping concentration is then optimized by comparing simulations with measurement data. The active depth of the depleted region of the MALTA2 sensor is estimated in both simulations and measurements using a grazing angle method, in which the sensor is positioned at various inclinations relative to the beam, covering angles from 0 to 60 degrees. Excellent agreement on active depth is obtained with the optimal doping concentration, showing a deviation of 2\% from the measured value at a threshold of 450\,$\text{e}^-$. Consequently, the framework offers a generic toolkit for sensor studies without requiring proprietary information.

physics.ins-det

A compact fibre-coupled active beamstop for fast time-resolved monitoring of synchrotron X-ray beams

We have developed a compact fibre-coupled active beamstop for simultaneous interception and time-resolved monitoring of the direct X-ray beam in synchrotron diffraction experiments. The complete beamstop tip has a maximum transverse dimension of 1 mm and incorporates a 700 $μ$m-wide Ce:YAG scintillator. The scintillator converts the intercepted X-rays into visible light, which is transported through a multimode optical fibre to a silicon photodiode at the bottom of the blade that is connected to a dedicated fast amplifier electronics. Tests with a pulsed laser yielded a system decay time of 69.4 ns, consistent with reported luminescence decay times for Ce:YAG. Measurements at the P14.EH2 end station of PETRA III demonstrated the detection of individual bunch signals separated by 192 ns in the 40-bunch operating mode. The active beamstop also provided an in-situ timing signal for synchronising an experimental sequence with the approximately 190 $μ$s transmission window of a mechanical X-ray chopper. The device therefore combines a compact obstruction of the direct beam with fast monitoring of X-ray timing and flux during diffraction data acquisition.

physics.ins-det

Charge-Carrier transport simulations in diamond detectors with electric-field-dependent mobility and charge-collection-distance-based trapping

Diamond detectors are attractive for operation in harsh radiation environments because they combine radiation tolerance, fast signal formation, and low leakage current. Realistic detector-response simulations require an accurate description of charge-carrier mobility and trapping, which determine both signal amplitude and timing. In this work, we extend \allpix{}, a modular end-to-end detector simulation framework, with diamond-specific transport models. The implementation includes field-dependent mobility parameterizations for electrons and holes and an effective trapping model based on the charge collection distance (CCD), providing a detector-level interface to material quality and radiation-damage measurements. The mobility description is validated in the negligible-trapping limit using single-crystalline CVD diamond by comparing simulated drift velocities and transient-current signals with published reference data. For polycrystalline CVD diamond, the CCD-based trapping model is evaluated using experimentally measured CCD values and compared with laboratory transient-current-technique waveforms. The simulations reproduce the measured drift-velocity behavior in scCVD and the reduced charge collection and degraded transient response observed in pcCVD. The presented implementation enables detector-level studies of charge collection, pulse formation, and timing performance in diamond sensors using experimentally accessible transport and trapping parameters, and provides a practical framework for simulation-driven detector development and radiation-damage studies.

physics.ins-det