Search arXivSearch

arXiv · 2502.00839

Integrated plasmo-photonic sensor with voltage controled detection

Abstract

In this paper, we propose and analyze a waveguide-integrated interferometric sensor in which interference occurs between two plasmonic modes propagating in a single plasmonic waveguide. For the purpose of sensing, the vertical plasmonic slot waveguide was rearranged by increasing the distance between the metal electrodes. Consequently, the plasmonic modes associated with each metal electrode have been separated, enabling them to propagate independently on opposing edges of metal electrodes what allows for the implementation of a Mach-Zehnder interferometer. The metal electrodes that support the plasmonic modes can also function as electrical contacts. By applying a DC voltage between them, it is possible to efficiently separate ions that drift to one of the metal electrodes. Consequently, any change in a transmission from the interferometer refers only to the amount of ions in a liquid as the output signal from the interferometer is normalized to a liquid by the reference arm which is in direct contact with the examined liquid solution. The total amount of ions in the examined liquid remains constant, however, what changes is their distribution in the gap as the ions drift toward one of the metal electrodes when a voltage is applied. The proposed configuration is highly sensitive to variations in transmission between the two arms of the interferometer, enabling a record sensitivity of over 12460 nm/RIU, even at the telecom wavelength of 1550 nm. A further enhancement in sensitivity is expected in the mid-infrared wavelengths, which correspond to the maximum absorption peaks of most chemical and biological compounds.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jacek Gosciniak, Ryszard Piramidowicz. 2025-02-02. Integrated plasmo-photonic sensor with voltage controled detection. https://arxiv.org/abs/2502.00839

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Active Fourier Spectroscopy: From fixed sampling protocols to adaptive measurement

Fourier-transform spectroscopy (FTS) is based on the Nyquist-Shannon theorem, which dictates a strict sampling protocol for the measurement of continuous signals. Here we introduce Active Fourier Spectroscopy (AFS), a generalization of FTS in which measurements are still taken in the Fourier-conjugate delay domain, but where the most informative acquisition points are selected adaptively and the spectrum is reconstructed by sequential, uncertainty-aware inference rather than by fixed-grid Fourier inversion. Our approach relies on a theoretical insight that the Nyquist condition applies only under complete ignorance about the system under investigation, and shows how to systematically improve upon it when prior knowledge exists. Because AFS recovers conventional FTS whenever the prior is uninformative, its performance never falls below that of conventional sampling. We demonstrate AFS for optical spectroscopy in three settings vital to research and medicine: clinical FTIR-based blood plasma analysis, optical metrology of structured laser beams, and hyperspectral imaging with an RGB camera. In each case AFS reaches a higher target reconstruction quality from far fewer acquisitions and provides complete uncertainty quantification in real time, propagated rigorously through downstream analysis.

physics.optics

Memory in Integrated Photonic Neural Networks: From Physical Mechanisms to Neuromorphic Architectures

The rapid scaling of artificial neural networks has exposed fundamental limitations of conventional von Neumann computing architectures. In these systems, the physical separation between memory and processing creates a bottleneck, as computational capabilities outpace the ability of memory and interconnects to supply and retrieve data. In contrast, biological neural systems inherently co-localize computation and memory through distributed, dynamical processes. Neuromorphic computing seeks to emulate this paradigm by leveraging physical substrates whose intrinsic dynamics simultaneously encode and process information. Among emerging platforms, silicon photoncis offer a compelling approach due to its high bandwidth, low-loss propagation, and inherent parallelism. This review examines the role of memory in integrated photonic neuromorphic systems, with emphasis on the physical mechanisms that provide volatile (short-term) and non-volatile (long-term) memory in silicon-on-insulator and hybrid silicon-on-insulator platforms. Drawing inspiration from digital, biological, and photonic memory architectures, we classify existing approaches based on their underlying physical principles. We cover implementations ranging from delay lines and slow-light structures to multistable dynamics and structural memory based on charge trapping and phase-change materials. We then discuss how these mechanisms support photonic neural network architectures, including feed-forward, reservoir computing, spiking and hybrid optoelectronic recurrent systems, and assess their relevance for time-dependent singal-processing tasks such as channel equalization in telecommunications. This review aims to establish a unified framework for understanding memory and learning in neuromorphic photonics and outlines key challenges and opportunities for scalable, energy-efficient neuromorphic hardware.

physics.optics

Exoplanet Detection Using Adaptive Quantum-Optimal Measurement

Detecting terrestrial exoplanets in the habitable zones of nearby stars remains a critical challenge. Such planets can be \(10^8\) to \(10^{10}\) times fainter than their host stars and lie at diffraction-limited angular separations, where starlight strongly obscures the companion signal. Here we present an adaptive quantum measurement method for estimating the number, positions, and brightnesses of mutually incoherent point sources in the sub-Rayleigh, ultra-high-contrast regime, operating at contrasts down to \(10^{-8}\) -- five orders of magnitude beyond previous quantum imaging approaches to exoplanet detection. The method adopts a spatial-mode basis that is updated to maximize the quantum Fisher information per detected photon. Estimation is performed by maximum likelihood in log-brightness coordinates, and the source count is determined by Bayesian-information-criterion (BIC) model selection directly from photon-count statistics, without a tunable detection threshold. For point sources within sub-Rayleigh separations and with brightness ratios spanning eight orders of magnitude, the method reconstructs complete scenes with a mean success rate of \(72.5\%\). Furthermore, it is robust to misalignment, maintaining a \(71.3\%\) success rate under offsets of up to six pixels. These results demonstrate that terrestrial exoplanets can be detected below the Rayleigh limit, a regime previously inaccessible to direct imaging.

physics.optics