Search arXivSearch

arXiv · 2502.01863

Technical description and performance of the phase II version of the Keck Planet Imager and Characterizer

Abstract

The Keck Planet Imager and Characterizer (KPIC) is a series of upgrades for the Keck II Adaptive Optics (AO) system and the NIRSPEC spectrograph to enable diffraction limited, high resolution (R>30000) spectroscopy of exoplanets and low mass companions in the K and L bands. Phase I consisted of single mode fiber injection/extraction units (FIU/FEU) used in conjunction with a H band pyramid wavefront sensor. The use of single mode fibers provides a gain in stellar rejection, a substantial reduction in sky background, and an extremely stable line spread function in the spectrograph. Phase II, deployed and commissioned in 2022, brought a 1000 actuator deformable mirror, beam shaping optics, a vortex mask, and other upgrades to the FIU/FEU. An additional service mission in 2024 extended operations down to y band, delivered an atmospheric dispersion corrector, and provided access to two laser frequency combs. KPIC phase II brings higher planet throughput, lower stellar leakage and many new observing modes which extend its ability to characterize exoplanets at high spectral resolution, building on the success of phase I. In this paper we present a description of the final phase II version of KPIC, along with results of system level laboratory testing and characterization showing the instrument's phase II throughput, stability, repeatability, and other key performance metrics prior to delivery and during installation at Keck. We outlined the capabilities of the various observing modes enabled by the new modules as well as efforts to compensate for static aberrations and non common path errors at Keck, which were issues that plagued phase I. Finally, we show results from commissioning.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Nemanja Jovanovic, Daniel Echeverri, Jacques-Robert Delorme, Luke Finnerty, Tobias Schofield, Jason J. Wang, Yinzi Xin, Jerry Xuan, J. Kent Wallacee, Dimitri Mawet, Aniket Sanghi, Ashley Baker, Randall Bartos, Charlotte Z. Bond, Benjamin Calvin, Sylvain Cetre, Greg Doppmann, Michael P. Fitzgerald, Jason Fucik, Maodong Gao, Jinhao Ge, Charlotte Guthery, Katelyn Horstman, Chih-Chun Hsud, Joshua Liberman, Stephanie Leifer, Scott Lilley, Ronald Lopez, Eduardo Marin, Emily C. Martin, Bertrand Mennesson, Evan Morris, Reston Nash, Jacklyn Pezzato, Michael Porter, Mitsuko Roberts, Garreth Ruane, Jean-Baptiste Ruffio, Ben Sappey, Eugene Serabyn, Boqiang Shen, Andrew Skemer, Ji Wang, Edward Wetherell, Peter Wizinowich, Maissa Salama, Vincent Chambouleyron, Rebecca Jensen-Clem, Chas Beichman. 2025-02-03. Technical description and performance of the phase II version of the Keck Planet Imager and Characterizer. https://doi.org/10.1117/1.jatis.11.1.015005

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Performance characterization of a new Structural and Thermal Architecture for a future spaceborne Closed-Cycle Dilution Refrigerator

A Structural and Thermal Model (STM) has been developed to support the new spaceborne Closed-Cycle Dilution Refrigerator (CCDR), which aims to provide continuous cooling at 100~mK for long-duration astrophysical missions. The STM is based on a hexapod architecture that ensures both thermal decoupling and mechanical robustness during launch. In this paper, we present the characterization of its thermal and mechanical performances. A dedicated experimental setup was used to investigate the thermal behavior of the STM across a broad temperature range. The study reveals limitations of the collar design, with incomplete power interception from thermal boundary resistances and vibration test failure traced to defective strut gluing. These results guide the next STM iteration with optimized collar and strut assembly for reliable CCDR operation in space.

astro-ph.IM

The Simons Observatory: Development of a Pipeline to Detect Rapid Transients in Time-Ordered Data

We introduce a method for detecting astrophysical transients evolving on timescales of milliseconds to minutes using cosmic microwave background (CMB) survey telescopes. While previous transient searches in CMB data operate in map space, our pipeline directly processes the raw time-ordered data, enabling sensitivity to fast, dynamic signals. We integrate our detection approach into the Simons Observatory time-domain pipeline and assess the performance by injecting symmetric, stellar flare-like light curves into simulated observations. For events flaring with a timescale of 0.5 s, the pipeline detects $\gtrsim90$ % of events at flux densities of 800, 1150, 1650, and 4250\,mJy when measured in the 93, 145, 225, and 280 GHz bands respectively. At a fixed peak flux density, the pipeline more readily detects longer flares. The limiting flux density for 90 % completeness is four times lower for a $\ge5$ s flare than for a 0.5 s flare, while the flux density limits for $\gtrsim50$ % detection efficiency are comparable to the rms noise of the time-ordered data. We are able to determine the position of detected events in each observing band, with a positional uncertainty at the detection threshold comparable to the telescope resolution at that band. These results demonstrate the readiness of this pipeline for incorporation into upcoming Simons Observatory data analyses.

astro-ph.IM

Thermal conductivity of various CFRPs from 100 mK to 20 K

Carbon-fiber-reinforced polymers (CFRPs) are some of the most useful materials for building spacecraft and aerospace tools. They are especially valuable for systems that work at extremely cold (cryogenic) temperatures because they are strong, lightweight, and don't transfer heat easily. In this study, researchers measured how well heat moves through several different types of carbon fiber samples, specifically T300, T700, HS40, M55J, and IMA, at different fiber layouts and densities. These measurements were taken at ultra-cold temperatures ranging from 100 mK to 20 K. The team used a newly developed analysis method to calculate the thermal conductivity for each sample. Finally, they shared how each material behaved at different temperatures and compared their findings to previous research.

astro-ph.IM