Search arXivSearch

arXiv · 2502.06171

A Synthetic Data-Driven Radiology Foundation Model for Pan-tumor Clinical Diagnosis

Abstract

AI-assisted imaging made substantial advances in tumor diagnosis and management. However, a major barrier to developing robust oncology foundation models is the scarcity of large-scale, high-quality annotated datasets, which are limited by privacy restrictions and the high cost of manual labeling. To address this gap, we present PASTA, a pan-tumor radiology foundation model built on PASTA-Gen, a synthetic data framework that generated 30,000 3D CT scans with pixel-level lesion masks and structured reports of tumors across ten organ systems. Leveraging this resource, PASTA achieves state-of-the-art performance on 45 of 46 oncology tasks, including non-contrast CT tumor screening, lesion segmentation, structured reporting, tumor staging, survival prediction, and MRI-modality transfer. To assess clinical applicability, we developed PASTA-AID, a clinical decision support system, and ran a retrospective simulated clinical trial across two scenarios. For pan-tumor screening on plain CT with fixed reading time, PASTA-AID increased radiologists' throughput by 11.1-25.1% and improved sensitivity by 17.0-31.4% and precision by 10.5-24.9%; additionally, in a diagnosis-aid workflow, it reduced segmentation time by up to 78.2% and reporting time by up to 36.5%. Beyond gains in accuracy and efficiency, PASTA-AID narrowed the expertise gap, enabling less-experienced radiologists to approach expert-level performance. Together, this work establishes an end-to-end, synthetic data-driven pipeline spanning data generation, model development, and clinical validation, thereby demonstrating substantial potential for pan-tumor research and clinical translation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Wenhui Lei, Hanyu Chen, Zitian Zhang, Luyang Luo, Qiong Xiao, Yannian Gu, Peng Gao, Yankai Jiang, Ci Wang, Guangtao Wu, Tongjia Xu, Yingjie Zhang, Pranav Rajpurkar, Xiaofan Zhang, Shaoting Zhang, Zhenning Wang. 2026-02-13. A Synthetic Data-Driven Radiology Foundation Model for Pan-tumor Clinical Diagnosis. https://arxiv.org/abs/2502.06171

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

JEVQA - Video Quality from Metadata, Bitstream, and Pixel Features with a General-Purpose Decision Model

Instrumental quality models for video quality prediction are usually trained for a fixed set of codecs or other input features, and every new input variable requires retraining. Novel, general-purpose decision models can answer questions without task-specific training, but it is unclear whether they can judge video quality. We evaluate Jev, a commercial ``System One'' model that returns probability distributions over a provided answer scale, as a zero-shot video quality model. We call the resulting method JEVQA. In a first study on 1,936 AV1, H.264, HEVC, and VP9 encodes of 22 sources, scored against VMAF as ground truth, using encoding metadata only, JEVQA reached a Pearson correlation of 0.737, on par with the standardized ITU-T P.1204.1 model (0.733). Giving the model bitstream data raised the accuracy to 0.797, and combined pixel-based and bitstream features raised it to 0.824. A pixel-only variant failed in our tests. In a second study, using H.264, HEVC, and VP9 encodes in the AVT-VQDB-UHD-1 database, the metadata-only model reached a correlation of 0.879 with MOS, close to P.1204.1 (0.898). Bitstream statistics did not help there. Our results show that trained models on the same features remain clearly ahead in both studies, but that zero-shot classifiers are promising.

eess.IV

When is a closed-form RGB->S/P ratio adequate? A hyperspectral characterization on natural scenes for mesopic display

Mesopic and low-light display transforms require, as their driving signal, a per-pixel scotopic-to-photopic luminance ratio (S/P); the exact spectral S/P is unavailable for ordinary RGB content, so a low-cost closed form that estimates S/P from a linear-RGB triplet is used in its place. Such closed forms exist but have been characterized only on narrowband / LED sources, i.e. spectrally sparse spectra, where a relative error of ~41% has been reported for a three-channel projection. Display content, however, is natural and broadband. We ask whether the same closed form is adequate there, using per-pixel spectral S/P from hyperspectral imagery as ground truth. On a daylight radiance time-series, a six-scalar closed form (three photopic and three scotopic channel weights) reproduces spectral S/P with a median error of ~0.07 that is time-invariant once the RGB input is chromatically adapted to D65; evaluated in un-adapted sRGB the error instead carries a color-temperature tilt across illuminants (~0.19), so adaptation is the enabling step for this use case. The result generalizes to an independent fifty-scene set (pooled median 0.024; 45/50 scenes within a pre-registered 0.10 band), with the few exceedances concentrated in saturated, spectrally-peaky surfaces that approach the narrowband regime (floral close-ups in this set). The scotopic weight vector is shown to be primary-model dependent, but the value used here is corroborated by a primary-free XYZ projection, and the median error stays within the band across all principled coefficient choices. We do not claim observer-validated appearance fidelity or adequacy on narrowband sources; both are out of scope. Both outcomes follow from the same three-channel projection: it is overwhelmed by spectrally sparse inputs and adequate on spectrally smooth ones.

eess.IV

Recurrent Convolutional Neural Networks for LiDAR-Based Attitude Initialization of Rotating Spacecraft

Accurate attitude estimation is essential for autonomous in-orbit servicing and proximity operations. This work proposes a Recurrent Convolutional Neural Network (RCNN) used in coarse attitude initialization of known, possibly tumbling spacecraft using LiDAR-derived depth images. By processing temporal sequences of 2D point-cloud projections, the RCNN effectively handles symmetries, occlusions, and degraded sensing. Simulations across various spacecraft geometries, angular velocities, and ranges show that the RCNN yields lower initialization errors and higher convergence rates than conventional CNN baseline within the adopted experimental framework, with performance varying across angular velocity conditions.

eess.IV