Search arXivSearch

arXiv · 2502.07117

Choroidal image analysis for OCT image sequences with applications in systemic health

Abstract

The choroid, a highly vascular layer behind the retina, is an extension of the central nervous system and has parallels with the renal cortex, with blood flow far exceeding that of the brain and kidney. Thus, there has been growing interest of choroidal blood flow reflecting physiological status of systemic disease. Optical coherence tomography (OCT) enables high-resolution imaging of the choroid, but conventional analysis methods remain manual or semi-automatic, limiting reproducibility, standardisation and clinical utility. In this thesis, I develop several new methods to analyse the choroid in OCT image sequences, with each successive method improving on its predecessors. I first develop two semi-automatic approaches for choroid region (Gaussian Process Edge Tracing, GPET) and vessel (Multi-scale Median Cut Quantisation, MMCQ) analysis, which improve on manual approaches but remain user-dependent. To address this, I introduce DeepGPET, a deep learning-based region segmentation method which improves on execution time, reproducibility, and end-user accessibility, but lacks choroid vessel analysis and automatic feature measurement. Improving on this, I developed Choroidalyzer, a deep learning-based pipeline to segment the choroidal space and vessels and generate fully automatic, clinically meaningful and reproducible choroidal features. I provide rigorous evaluation of these four approaches and consider their potential clinical value in three applications into systemic health: OCTANE, assessing choroidal changes in renal transplant recipients and donors; PREVENT, exploring choroidal associations with Alzheimer's risk factors at mid-life; D-RISCii, assessing choroidal variation and feasibility of OCT in critical care. In short, this thesis contributes many open-source tools for standardised choroidal measurement and highlights the choroid's potential as a biomarker in systemic health.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jamie Burke. 2025-02-10. Choroidal image analysis for OCT image sequences with applications in systemic health. https://doi.org/10.7488/era%2F5507

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

IViT: A Novel Interpretable Visual Transformer for Skin Disease Detection

The clinical diagnosis of skin diseases is susceptible to interference from inter-class similarity of skin lesions, and over-reliance on clinicians'experience easily leads to subjective bias. Although existing deep learning aided diagnosis methods achieve competitive accuracy, they suffer from the black-box opacity of Vision Transformer (ViT) and poor adaptability to medical few-shot scenarios. Moreover, mainstream explainable algorithms generally face the bottleneck of significant accuracy degradation when improving interpretability. This paper proposes an interpretable ViT (IViT) constrained by Quadratic Programming (QP). The introduced pre-trained transfer learning adapts to few-shot feature extraction. A discrete QP feature selection framework is constructed to screen generic and discriminative features consistent with clinical diagnostic logic. A multi-objective loss function is designed to reduce feature redundancy and optimize activation distribution while preserving classification performance. Experimental results on six standard skin disease datasets show that IViT achieves an accuracy of 93.80%, only 0.21% lower than the baseline, with feature redundancy reduced by 29.5%. Its core activation regions are consistent with clinically concerned lesion areas. The proposed model balances accuracy and interpretability, providing a reliable solution for the clinical deployment of few-shot intelligent skin disease diagnosis.

eess.IV

Automated Distinction of Intimal and Medial Intracranial Arterial Calcification from CT Head

Intracranial arterial calcifications (IACs) are a common finding on clinical non-contrast enhanced head CT scans and are associated with neurovascular disease. Calcifications can occur in the intimal or medial layer of the arterial wall, subtypes that differ in aetiology and may have distinct clinical relevance. These subtypes can be visually distinguished by radiologists based on the shape of the calcifications. We investigate three automated approaches for subtype classification of IAC from head CT-derived segmentation masks: (1) an automated adaptation of the established radiological visual score, (2) a sphericity-based method, and (3) a method based on shape embeddings extracted by a medical shape foundation model. All approaches use the same lightweight classification pipeline on top of the features they compute and are evaluated using 5-fold cross-validation. The three methods achieved comparable performance, with the embedding-based approach yielding the best overall results with a weighted F1 (mean $\pm$ SD) of up to 71.5 $\pm$ 3.7 for a single artery and 59.8 $\pm$ 1.7 for the joint artery classification. Performance was largely preserved when using automated instead of manual IAC segmentation masks, and we found the difference in weighted F1 not significant. Our results show that fully automated IAC subtype quantification from head CT is feasible and remains robust to the use of manual and automated IAC segmentation masks. Code at https://github.com/bjin96/iac-subtyping.

eess.IV

Recasting the Destroy Step of Large Neighborhood Search as Dense Segmentation

Large neighborhood search improves an incumbent by releasing selected variables and repairing the resulting subproblem under a time limit. FOVEA casts variable selection as dense semantic segmentation on a fixed $128\times128$ canvas. A small U-Net reads twelve semantic channels and predicts cell scores, which are decoded into a variable set subject to a fixed variable budget. Family-specific layouts connect the search state to the canvas, while one set of network weights serves four problem families. The FP32 network input occupies $786$\,kB across instance sizes. Our analysis bounds constraint coupling for spatially coherent regions, gives a rank certificate for rounds with zero possible improvement, and bounds the coupling advantage attainable on an expander family. On the tested families and hardware, FOVEA trails the strongest graph encoder at $10^{4}$ variables and overtakes it near $1.5\times10^{4}$; the cost model provides an approximate crossover estimate. At larger sizes, where the graph-encoder baselines exceed device memory, FOVEA reduces the primal integral by $12$ to $16\%$ relative to the best runnable baselines. On the expander family, FOVEA performs comparably to random selection, with a coupling advantage close to one.

eess.IV