Search arXivSearch

arXiv · 2502.07359

Towards energy-insensitive and robust neutron/gamma classification: A learning-based frequency-domain parametric approach

Abstract

Neutron/gamma discrimination has been intensively researched in recent years, due to its unique scientific value and widespread applications. With the advancement of detection materials and algorithms, nowadays we can achieve fairly good discrimination. However, further improvements rely on better utilization of detector raw signals, especially energy-independent pulse characteristics. We begin by discussing why figure-of-merit (FoM) is not a comprehensive criterion for high-precision neutron/gamma discriminators, and proposing a new evaluation method based on adversarial sampling. Inspired by frequency-domain analysis in existing literature, parametric linear/nonlinear models with minimum complexity are created, upon the discrete spectrum, with tunable parameters just as neural networks. We train the models on an open-source neutron/gamma dataset (CLYC crystals with silicon photomultipliers) preprocessed by charge normalization to discover and exploit energy-independent features. The performance is evaluated on different sampling rates and noise levels, in comparison with the frequency classification index and conventional methods. The frequency-domain parametric models show higher accuracy and better adaptability to variations of data integrity than other discriminators. The proposed method is also promising for online inference on economical hardware and portable devices.

Explore related subjects

Keep this discovery

BibTeXRIS

Pengcheng Ai, Hongtao Qin, Xiangming Sun, Kaiwen Shang. 2025-02-11. Towards energy-insensitive and robust neutron/gamma classification: A learning-based frequency-domain parametric approach. https://doi.org/10.1016/j.net.2025.103667

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det