Design and Implementation of a UDP-Based Command Interface for the INO ICAL Experiment

Abstract

Efficient command interface is a critical requirement for experiments employing a large number of front-end DAQ modules and control servers. In the context of the INOICAL (India-based Neutrino Observatory Iron Calorimeter) experiment, this involves 28,800 Resistive Plate Chamber(RPC), charged particle detectors. The acquisition and control of these detectors are facilitated through Front End data acquisition modules known as RPC-DAQs. These modules consists of Ethernet interfaces for data and command connectivity to a server. Each module acts as a network node with a unique IP address. The collective group of hundreds of modules is controlled by a common server over a Local Area Network (LAN). UDP (User Datagram Protocol) is the most commonly used networking protocol which supports Multicast as well as Unicast, can be easily adapted to INO ICAL Experiment. A server can send commands to group of DAQs or any particular DAQ. But UDP may have the problem of packet loss and reliability. To mitigate these issues, this paper suggests a simpler approach that modifies the UDP protocol by implementing a handshaking scheme and checksum, similar to those found in more reliable protocols like TCP. The proposed solution optimizes the use of UDP as a reliable command interface in the INO ICAL experiment, ensuring seamless data acquisition and control. Also, this paper shows the performance study of the custom hybrid UDP Command Interface in the prototype ICAL experiment called Mini Iron Calorimeter (Mini ICAL) which houses 20 units of RPCs and electronics. This work not only addresses the challenges of the INO ICAL experiment but also underscores the adaptability and robustness of the proposed protocol for usage in mini-ICAL and beyond.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Yuvaraj Elangovan, Mandar Saraf, B. Satyanarayana, S. S. Upadhya, Nagaraj Panyam, Ravindra Shinde, Gobinda Majumder, D. Sil, Pathaleswar, K. C. Ravindran, Upendra Gokhale, Pavan Kumar. 2026-02-26. Design and Implementation of a UDP-Based Command Interface for the INO ICAL Experiment. https://arxiv.org/abs/2503.02751

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det