Quality assurance tests and techniques to investigate and improve hermeticity of ATLAS Phase II Resistive Plate Chamber detectors

Abstract

The Phase II upgrade of the ATLAS Muon Spectrometer will involve the installation of approximately 1000 next-generation Resistive Plate Chamber (RPC) singlets. This upgrade aims to enhance detector coverage, increase hit efficiency, and improve timing precision, ultimately strengthening the precision and robustness of the muon trigger system. The upgrade is essential for maintaining the performance of the muon spectrometer in the high-luminosity environment of the HL-LHC, where increased radiation and event rates pose significant challenges. Currently, detector production is underway, with gas gaps being commercially produced in Italy. To ensure the integrity of these gas gaps, especially their mechanical properties and gas tightness, several investigative techniques have been proposed and implemented. This study discusses the results of Thermal Cycling tests performed on ATLAS RPC gas gaps. These tests were conducted between $-33^{\circ}$C and $+35^{\circ}$C in a climate room at University of Cambridge and $-20^{\circ}$C and $+30^{\circ}$C in laboratories at INFN Frascati, providing insights into the effects of mechanical stress due to thermal expansion on gas leaks. Additionally, it outlines various methods employed to assess and enhance the gas tightness of the detectors. The ultimate objective is to produce hermetic RPC detectors, minimising the emission of environmentally harmful gases and mitigating their impact on global warming.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Aashaq Shah. 2025-06-20. Quality assurance tests and techniques to investigate and improve hermeticity of ATLAS Phase II Resistive Plate Chamber detectors. https://doi.org/10.1016/j.nima.2025.170510

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det