Search arXivSearch

arXiv · 2503.06032

APEX: Optimized vertical drift PDS for DUNE FD3

Abstract

The Deep Underground Neutrino Experiment currently under construction in the US will be a long-baseline neutrino oscillation experiment dedicated to determining the neutrino mass ordering and to measure the CP violation phase in the lepton sector. DUNE will also perform studies of non-beam physics such as atmospheric neutrinos, bursts from supernovae and nucleon decays in which photon detection systems will play a major role in triggering and also provide calorimetric measurements. For the second phase of DUNE, two additional detector modules will be added in the far detector complex in the Sanford Underground Research Facility. We present the Aluminum Profiles with Embedded X-ARAPUCA (APEX) concept as an advanced proposal for the photon detector system of the third DUNE far detector module. This system aims to have an optical coverage of approximately 60% made viable by the technology advancement achieved by the DUNE collaboration on the use of non-conductive optical fibers for power and signal readout of the photon detector units. Such large coverage will provide enhanced light collection capabilities at MeV-scale energy deposit level per interaction and optimal energy reconstruction resolution up to the GeV scale. The attained electrical isolation of the detector units with low noise levels allows for a complete instrumentation of the field cage walls with satisfactory segmentation as the readout scheme envisages a much larger than typical number of channels to be adopted. We discuss the main features of the system, first estimates on its expected performances, potential for physics measurements and prototyping plans for R\&D.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F. Marinho. 2025-04-17. APEX: Optimized vertical drift PDS for DUNE FD3. https://arxiv.org/abs/2503.06032

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Search for dark matter in a signature with a four-prong large-radius jet in proton-proton collisions at $\sqrt{s}$ = 13 TeV

A search for a pair of nonprompt dark matter (DM) candidates produced in association with an initial-state radiation jet, in a signature containing a four-prong large-radius jet, is presented. The signal model contains a heavy vector or axial-vector mediator, which produces long-lived dark-sector particles that decay to a stable DM particle and a light boson, which decays to quarks. The analysis is based on data collected in the years 2016$-$2018 with the CMS detector at the LHC in proton-proton collisions at $\sqrt{s}$ = 13 TeV, corresponding to an integrated luminosity of 138 fb$^{-1}$. Signal candidates feature large-radius jets, which are identified using a jet substructure tagger based on a graph neural network. The large-radius jet aims to reconstruct the decay of light DM mediators into four quarks, which are produced in association with two stable DM particles. The standard model background contributions are estimated from data using dedicated control regions. The missing transverse momentum spectrum is probed for a potential signal over the expected background. No significant excess over the standard model expectation is observed. Upper limits at 95% confidence level are set on the signal strength as functions of either the mediator mass or the relevant coupling. This is the first search for a pair of nonprompt DM candidates in the Lorentz-boosted topology, characterized by a large-radius jet and large missing transverse momentum.

hep-ex

Charge-dependent atmospheric muon flux at 17 GV geomagnetic cutoff with the mini-ICAL detector

The Iron CALorimeter (ICAL) detector at the India-Based Neutrino Observatory (INO) was conceived as an underground experiment designed to measure atmospheric neutrino oscillation parameters. As part of the R\&D programme, a scaled prototype (mini-ICAL), 85\,ton, approximately 1/600$^{\mathrm{th}}$ the mass of the full detector, was constructed at the IICHEP Transit Campus, Madurai (altitude 150\,m; latitude 9.9372$^\circ$\,N; longitude 78.013$^\circ$\,E; geomagnetic latitude 1.44$^\circ$\,N; vertical cutoff rigidity 17\,GV) and operated between 2018 and 2022. The prototype enabled measurements of charge-dependent cosmic muon spectra in the vicinity of the geomagnetic equator and provided an important validation of detector performance, reconstruction algorithms, and simulation frameworks for the ICAL experiment. Differential fluxes of $μ^{-}$ and $μ^{+}$ were measured over the momentum range $\sim$\,1--5\,GeV/c. The obtained momentum spectra are systematically lower than those reported at sites with smaller geomagnetic cutoff rigidities, consistent with the suppression of low- and intermediate-rigidity primary cosmic rays at the 17\,GV cutoff. The measurements are compared with predictions from different hadronic interaction models available in CORSIKA simulations.

hep-ex

Laboratory constraints on peV-scale mass splitting between ordinary and sterile neutron states

Sterile states of matter, represented by a parallel ``mirror'' sector, may contribute to the observed dark matter in the Universe. We investigated the parameter space of neutron $(n)$ to mirror-neutron $(n')$ oscillations, in the case where the two states are not necessarily mass-degenerate, taking into account interactions in the mirror sector. By tuning the magnitude of an applied magnetic-field in the range $5~μ\mathrm{T} < B < 360~μ\mathrm{T}$ to corresponding resonance conditions for finite mass splitting, we derive exclusion limits for the $n-n'$ oscillation time constant reaching about $20~\text{s}$ over the mass-difference range $0.3 - 22~\text{peV}$. In parts of this parameter range, our limits exceed the model-dependent neutron-star-cooling bound, providing the first experimental constraints in this scenario that are more stringent than this astrophysical estimate.

hep-ex