Search arXivSearch

arXiv · 2503.09559

Interlaced R2D2 DNN Series for Scalable Non-Cartesian MRI with Sensitivity Self-calibration

Abstract

We introduce interlaced R2D2 (iR2D2), a DNN series paradigm for scalable image reconstruction from accelerated non-Cartesian k-space acquisitions in MRI with sensitivity map self-calibration. While unrolled DNN architectures provide robust image formation, embedding non-uniform fast Fourier transform operators within the backpropagation graph becomes impractical to train at large scale, e.g., in 2D MRI with a large number of coils, or for higher-dimensional imaging. To address this scalability challenge, we leverage the R2D2 paradigm as a learned version of the Matching Pursuit algorithm that was recently introduced in radio astronomy for fast large-scale Fourier imaging. R2D2's reconstruction is formed as a series of residual images iteratively estimated as outputs of DNN modules taking the previous iteration's data residual as input. Specific to MRI, precomputed sensitivity maps derived from undersampled data can yield an inaccurate measurement operator, which may adversely affect the performance of iterative algorithms such as R2D2. Thus, we extend the R2D2 framework to iR2D2 by introducing a bespoke interlaced architecture that alternates between two R2D2 DNN series to jointly self-calibrate sensitivity maps and form the MR image. We further enhance iR2D2 to operate as an adaptive solver governed by an error-controlled update condition that enforces a sufficient residual energy descent, a dynamic capability fundamentally incompatible with the predefined forward passes of unrolled architectures. Extensive experiments in simulation and on real data, targeting undersampled radial k-space sampling, demonstrate that iR2D2 significantly improves upon R2D2 and outperforms state-of-the-art benchmarks, delivering scalable, high-fidelity imaging with corrected sensitivity profiles.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Shijie Chen, Yiwei Chen, Amir Aghabiglou, Motahare Torki, Chao Tang, Ruud B. van Heeswijk, Yves Wiaux. 2026-05-02. Interlaced R2D2 DNN Series for Scalable Non-Cartesian MRI with Sensitivity Self-calibration. https://arxiv.org/abs/2503.09559

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Dipole-lets: a new multiscale decomposition for MR phase and quantitative susceptibility mapping

Nondipolar phase contributions can generate severe streaking artifacts during quantitative susceptibility mapping (QSM) inversion. We propose Dipole-lets, a dipole-adapted multiscale decomposition designed to identify phase components associated with streaking artifacts before and during susceptibility inversion. Dipole- lets combine an undecimated radial decomposition with an angular partition based on proximity to the magic cone. The resulting coefficients emphasize phase components near the magic cone, where nondipolar contributions may become relatively prominent. This information was incorporated into QSM reconstruction through a data- driven fidelity weight and a Dipole-let-based regularizer that models an additional nondipolar phase component. The methods were evaluated using modified simulated QSM data and an in vivo dataset. The data-driven weighting reduced streaking artifacts while preserving anatomical detail and improved quantitative reconstruction metrics compared with magnitude-weighted TV. The Dipole-let regularizer achieved streaking suppression comparable to L1-QSM and lower reconstruction error in the modified simulated dataset. In vivo experiments further demonstrated the applicability of the proposed approach to data with strong susceptibility-induced phase perturbations. Dipole-lets provide a multiscale representation for characterizing phase components associated with streaking artifacts and incorporating this information into QSM reconstruction, reducing streaking while preserving relevant susceptibility structures, and providing a flexible basis for future QSM reconstruction methods.

eess.IV

MTMed3D: A Multi-Task Transformer-Based Model for 3D Medical Imaging

In the field of medical imaging, AI-assisted techniques such as object detection, segmentation, and classification are widely employed to alleviate the workload of physicians and doctors. However, single-task models are predominantly used, overlooking the shared information across tasks. This oversight leads to inefficiencies in real-life applications. In this work, we propose MTMed3D, a novel end-to-end Multi-task Transformer-based model to address the limitations of single-task models by jointly performing 3D detection, segmentation, and classification in medical imaging. Our model uses a Transformer as the shared encoder to generate multi-scale features, followed by CNN-based task-specific decoders. The proposed framework was evaluated on the BraTS 2018 and 2019 datasets, achieving promising results across all three tasks, especially in detection, where our method achieves better results than prior works. Additionally, we compare our multi-task model with equivalent single-task variants trained separately. Our multi-task model significantly reduces computational costs and achieves faster inference speed while maintaining comparable performance to the single-task models, highlighting its efficiency advantage. To the best of our knowledge, this is the first work to leverage Transformers for multi-task learning that simultaneously covers detection, segmentation, and classification tasks in 3D medical imaging, presenting its potential to enhance diagnostic processes. The code is available at https://github.com/fanlimua/MTMed3D.git.

eess.IV

VideoPulse: Neonatal heart rate and peripheral capillary oxygen saturation (SpO2) estimation from contact free video

Remote photoplethysmography (rPPG) enables contact free monitoring of vital signs and is especially valuable for neonates, since conventional methods often require sustained skin contact with adhesive probes that can irritate fragile skin and increase infection control burden. We present VideoPulse, a neonatal dataset and an end to end pipeline that estimates neonatal heart rate and peripheral capillary oxygen saturation (SpO2) from facial video. VideoPulse contains 157 recordings totaling 2.6 hours from 52 neonates with diverse face orientations. Our pipeline performs face alignment and artifact aware supervision using denoised pulse oximeter signals, then applies 3D CNN backbones for heart rate and SpO2 regression with label distribution smoothing and weighted regression for SpO2. Predictions are produced in 2 second windows. On the NBHR neonatal dataset, we obtain heart rate MAE 2.97 bpm using 2 second windows (2.80 bpm at 6 second windows) and SpO2 MAE 1.69 percent. Under cross dataset evaluation, the NBHR trained heart rate model attains 5.34 bpm MAE on VideoPulse, and fine tuning an NBHR pretrained SpO2 model on VideoPulse yields MAE 1.68 percent. These results indicate that short unaligned neonatal video segments can support accurate heart rate and SpO2 estimation, enabling low cost non invasive monitoring in neonatal intensive care.

eess.IV