Search arXivSearch

arXiv · 2503.15721

Minimal material, maximum coverage: Silicon Tracking System for high-occupancy conditions

Abstract

Silicon strip sensors have long been a reliable technology for particle detection. Here, we push the limits of silicon tracking detectors by targeting an unprecedentedly low material budget of 2%-7% $X_0$ in an 8-layer 4 m$^2$ detector designed for high-occupancy environments ($\leq$ 10 MHz/cm$^2$). To achieve this, we employ Double-Sided Double Metal (DSDM) silicon microstrip sensors, coupled with readout electronics capable of precise timing and energy measurements. These 320 $μ$m thick sensors, featuring $2\times 1024$ channels with a 58 $μ$m pitch, are connected via ultra-lightweight aluminium-polyimide microcables for signal transmission and integrated with a custom SMX readout ASIC, operating in free-streaming mode. This system enables the simultaneous measurement of time ($Δt \simeq 5$~ns) and charge deposition (0.1-100 fC), significantly enhancing the detector's capacity for high-precision track reconstruction in high-occupancy and harsh radiation field environments. The primary application of this technology is the Silicon Tracking System (STS) for the CBM experiment, with additional potential in projects like the J-PARC E16 experiment and future uses in medical physics, such as advanced imaging telescopes. In this contribution, we present the current status of CBM STS construction, with almost one-third of the modules produced and tested. We also discuss immediate applications and explore promising prospects in both scientific and medical fields.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M. Teklishyn, L. M. Collazo Sánchez, U. Frankenfeld, J. M. Heuser, O. Kshyvanskyi, J. Lehnert, D. A. Ramírez Zaldivar, D. Rodríguez Garcés, A. Rodríguez Rodríguez, C. J. Schmidt, P. Semeniuk, M. Shiroya, A. Sharma, A. Toia, O. Vasylyev. 2025-03-19. Minimal material, maximum coverage: Silicon Tracking System for high-occupancy conditions. https://arxiv.org/abs/2503.15721

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det