Search arXivSearch

arXiv · 2503.22561

Depolarization studies on low-depolarizing Cu/Ti and Ni(Mo)/Ti neutron supermirrors

Abstract

Neutron supermirrors (SMs) are a crucial part of many scattering and particle physics experiments. So far, Ni(Mo)/Ti SMs have been used in experiments that require to transport a polarized neutron beam due to their lower saturation magnetization compared to Ni/Ti SMs. However, next generation $β$ decay experiments require SMs that depolarize below $10^{-4}$ per reflection to reach their targeted precision. The depolarization of a polarized neutron beam due to reflection from Ni(Mo)/Ti SMs has not yet been measured to that precision. Recently developed Cu/Ti SMs with a very low saturation magnetization compared to Ni(Mo)/Ti may serve as an alternative. In this paper, we test the performance of both mirrors. At a first stage, we present four-states polarized neutron reflectivity (PNR) curves of Ni(Mo) and Cu monolayers measured at the neutron reflectometer SuperADAM and perform a full polarization analysis, showing a difference between the magnetic scattering length density (mSLD) of both materials, with Cu having a lower mSLD than Ni(Mo). These results are corroborated with the full polarization analysis of four-states PNR curves of $m=2$ Ni(Mo)/Ti and Cu/Ti SMs. In a second stage, we measured the depolarization ($D$) that a polarized neutron beam suffers after reflection from the same Ni(Mo)/Ti and Cu/Ti SMs by using the Opaque Test Bench setup. We find upper limits for the depolarization of $D_\text{Cu/Ti(4N5)}<7.6\times 10^{-5}$, $D_\text{Ni(Mo)/Ti}<8.5\times 10^{-5}$, and $D_\text{Cu/Ti(2N6)}<6.0\times 10^{-5}$ at the $1σ$ confidence level, where (4N5) corresponds to a Ti purity of $99.995\%$ and (2N6) to $99.6\%$. The uncertainties are statistical. These results show that all three SMs are suitable for being used in next generation $β$ decay experiments. We found no noticeable dependence of $D$ on the $q$ value or the magnetizing field, in which the samples were placed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jose Manuel Gómez-Guzmán, Karina Bernert, Anton Devishvili, Christine Klauser, Bastian Märkisch, Ulrich Schmidt, Torsten Soldner. 2025-03-28. Depolarization studies on low-depolarizing Cu/Ti and Ni(Mo)/Ti neutron supermirrors. https://doi.org/10.1016/j.nima.2025.170795

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det

Characterization of immersed SiPM arrays in liquid scintillator between room temperature and $-30\,^{\circ}\mathrm{C}$

Liquid scintillator detectors instrumented with distributed silicon photomultiplier (SiPM) arrays can be used in compact, topology-sensitive, and low-background experiments, but the temperature dependence of SiPMs immersed directly in the scintillation medium has not been widely characterized. We report the operation of a 125-liter linear-alkylbenzene-based liquid scintillator detector read out by 125 SiPM channels immersed in the active volume, over the range from room temperature to $-30\,^{\circ}\mathrm{C}$. The detector response was measured with cosmic-ray muons, including stopping muons followed by their Michel-electron decay. Cooling from $+15\,^{\circ}\mathrm{C}$ to $-30\,^{\circ}\mathrm{C}$ reduced the SiPM dark-count rate by a factor of 13.5, increased the single-photoelectron response by 49.1%, and increased the cosmic-ray muon light yield by 16.7%. The improved photoelectron separation and baseline stability at low temperature enabled a selection of stopping-muon events, from which the effective muon lifetime was measured to be $1959\pm132\,\mathrm{ns}$, consistent with the value expected for a hydrocarbon scintillator once $μ^{-}$ capture on carbon is taken into account.

physics.ins-det