Search arXivSearch

arXiv · 2504.19708

Relative Spectral Response Function Retrieval of Hyperspectral Instruments in Atmospheric Spectrometry

Abstract

Nowadays, tens of satellites carry hyperspectral spectrometers. Such instruments allow decomposing the light that exits the atmosphere from its top into hundreds to thousands of contiguous spectral channels. By analysis of the light spectral distribution, and in particular the depths of selected absorption lines, researchers and meteorological agencies can retrieve the atmosphere composition and thermodynamic state. To get a global view of the Earth, several instruments are generally operated synergistically, therefore, a harmonized calibration must be achieved between them. To cross-calibrate two spectrometers, a common practice is to analyze an ensemble of collocated measurements, meaning acquisitions performed at the same time and under the same geometry. Nonetheless, such analysis always faces the issue of setting appropriate temporal and geometric thresholds in defining the collocations, trading off between statistics and quality. Consequently, some collocation mismatches may have a substantial impact on the cross-calibration results. Thus, the following manuscript describes in detail the inclusion of collocation errors into the mathematical description and presents an application which is designed on purpose to be robust to such errors. Then, the knowledge of the spectral sensitivities of each channel to the incoming light, called the spectral response functions (SRF), are key to the exploitation of the acquisitions. In that context, the authors have studied and designed a novel methodology to retrieve relative SRF between two or more spectrometers, within a single instrument or between instruments embarked on different platforms. The objective of the methodology is to characterize discrepancies of responses between flying spectrometers, track long-term evolutions and harmonize their responses with post-processing when necessary.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Pierre Dussarrat, Guillaume Deschamps. 2025-04-28. Relative Spectral Response Function Retrieval of Hyperspectral Instruments in Atmospheric Spectrometry. https://arxiv.org/abs/2504.19708

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det