Search arXivSearch

arXiv · 2504.20755

Low dose gamma irradiation study of ATLAS ITk MD8 diodes

Abstract

Silicon strip detectors developed for the Inner Tracker (ITk) of the ATLAS experiment will operate in a harsh radiation environment of the HL-LHC accelerator. The ITk is thus designed to endure a total fluence of 1.6E15 1MeV n_eq/cm2 and a total ionizing dose (TID) of 66 Mrad in the strip detector region. A radiation-hard n^+-in-p technology is implemented in the ITk strip sensors. To achieve the required radiation hardness, extensive irradiation studies were conducted during sensor development, primarily performed up to the maximal expected total fluence and TID to ensure a full functionality of the detector at its end-of-life. These studies included irradiations of sensors with various particle types and energies, including the Co60 gamma-rays. Our previous results obtained for gamma-irradiated diodes and strip sensors indicate a linear increase of bulk current with TID, while the surface current saturates at the lowest TID levels checked (66 Mrad), preventing a determination of the exact TID for which the observed saturation occurs. This work presents the results coming from irradiations by Co60 gamma-rays to multiple low TIDs, ranging from 0.5 to 100 krad. The detailed study of total, bulk, and surface currents of diodes explores an unknown dependence of surface current on the TID, annealing, and temperature. Additionally, the effect of the p-stop implant between the bias and the guard ring of measured samples is shown. The observations are relevant for the initial operations of the new ATLAS tracker.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M. Mikeštíková, V. Fadeyev, P. Federičová, P. Gallus, J. Kozáková, J. Kroll, M. Kůtová, J. Kvasnička, P. Tůma, M. Ullán, Y. Unno. 2026-02-18. Low dose gamma irradiation study of ATLAS ITk MD8 diodes. https://arxiv.org/abs/2504.20755

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det