Search arXivSearch

arXiv · 2505.00042

Characterisation of the neutron beam in the n_TOF-EAR2 experimental area at CERN following the spallation target upgrade

Abstract

The n_TOF facility at CERN has undergone a major upgrade after the installation of a new spallation target, designed to improve the features of both neutron beamlines at the experimental areas 1 and 2 (EAR1 and EAR2) and the commissioning of a new experimental area (NEAR). Due to improved coupling of the spallation target with the EAR2 beamline, the upgrade resulted in a significantly increased neutron flux and improved neutron energy resolution. This paper presents the results of the commissioning phase that followed to characterise the EAR2 neutron beamline and validate the FLUKA Monte Carlo simulations of the facility. The main features of the neutron beam, namely the neutron flux, spatial profile and energy resolution, are evaluated and compared to the previous target. The neutron flux presents a general increase of 20% below 1 eV, 40% between 1 eV and 100 keV and 50% between 100 keV and 10 MeV. The measured width of the beam profile was 3 cm (FWHM) at the reference position for neutron capture measurements. The energy resolution with the new spallation target shows a significant improvement compared to the previous one. Moreover, FLUKA Monte Carlo simulations present a good agreement with the measured neutron flux and profile within uncertainties, and a remarkable reproduction of the energy resolution.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J. A. Pavon-Rodriguez, J. Lerendegui-Marco, A. Manna, S. Amaducci, M. Sabate-Gilarte, E. Musacchio-Gonzalez, M. Bacak, V. Alcayne, M. A., Cortes-Giraldo, V. Vlachoudis, R. Zarrella, F. Garcia-Infantes, E. Stamati, A. Casanovas, N. Patronis, L. Tassan-Got, J. M. Quesada, the n_TOF Collaboration. 2025-10-29. Characterisation of the neutron beam in the n_TOF-EAR2 experimental area at CERN following the spallation target upgrade. https://arxiv.org/abs/2505.00042

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det

Characterization of immersed SiPM arrays in liquid scintillator between room temperature and $-30\,^{\circ}\mathrm{C}$

Liquid scintillator detectors instrumented with distributed silicon photomultiplier (SiPM) arrays can be used in compact, topology-sensitive, and low-background experiments, but the temperature dependence of SiPMs immersed directly in the scintillation medium has not been widely characterized. We report the operation of a 125-liter linear-alkylbenzene-based liquid scintillator detector read out by 125 SiPM channels immersed in the active volume, over the range from room temperature to $-30\,^{\circ}\mathrm{C}$. The detector response was measured with cosmic-ray muons, including stopping muons followed by their Michel-electron decay. Cooling from $+15\,^{\circ}\mathrm{C}$ to $-30\,^{\circ}\mathrm{C}$ reduced the SiPM dark-count rate by a factor of 13.5, increased the single-photoelectron response by 49.1%, and increased the cosmic-ray muon light yield by 16.7%. The improved photoelectron separation and baseline stability at low temperature enabled a selection of stopping-muon events, from which the effective muon lifetime was measured to be $1959\pm132\,\mathrm{ns}$, consistent with the value expected for a hydrocarbon scintillator once $μ^{-}$ capture on carbon is taken into account.

physics.ins-det