Search arXivSearch

arXiv · 2505.00851

The Telescope Calibration of the Imaging X-ray Polarimetry Explorer

Abstract

Fifty years after the very first sounding rocket measurement of cosmic X-ray polarization, the Imaging X-ray Polarimetry Explorer (IXPE) mission has effectively opened a new window into the X-ray sky. Prior to launch of IXPE, an extensive calibration campaign was carried out to fully characterize the response of this new type of instrument. Specifically, the polarization-sensitive detectors were intensively calibrated in Italy, where they were developed and built. The X-ray optics, which collect and focus X rays onto the detectors, were built and calibrated in the U.S. A key question was whether the telescope (optics + detectors) calibrations could be synthesized from the individual component calibrations, avoiding time consuming and costly end-to-end calibrations for a flight program with a fixed schedule. The data presented here are from a calibration of the flight spare telescope utilizing the flight spare detector and flight spare mirror assembly combined. These data show that the presence of the mirror module does not affect the polarization response of the detectors (within the required calibration accuracy) and that the angular resolution of the telescopes could be accurately determined. Thus, the original extensive stand-alone ground calibration data of all the flight detectors and all the flight optic can be utilized in full to derive the flight telescopes calibrations.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Brian Ramsey, Jeffery Kolodziejczak, Wayne Baumgartner, Nicholas Thomas, Stephen Bongiorno, Phillip Kaaret, Stephen O'Dell, Allyn Tennant, Martin C. Weisskopf, Sergio Fabiani, Fabio Muleri, Paolo Soffitta, Enrico Costa, Alessandro Di Marco, Riccardo Ferrazzoli, Fabio La Monaca, John Rankin, Ajay Ratheesh, Alessio Trois, Luca Baldini, Ronaldo Bellazzini, Alessandro Brez, Luca Latronico, Leonardo Lucchesi, Alberto Manfreda, Massimo Minuti, Leonardo Orsini, Michele Pinchera, Carmelo Sgro, Gloria Spandre. 2025-05-01. The Telescope Calibration of the Imaging X-ray Polarimetry Explorer. https://arxiv.org/abs/2505.00851

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Performance characterization of a new Structural and Thermal Architecture for a future spaceborne Closed-Cycle Dilution Refrigerator

A Structural and Thermal Model (STM) has been developed to support the new spaceborne Closed-Cycle Dilution Refrigerator (CCDR), which aims to provide continuous cooling at 100~mK for long-duration astrophysical missions. The STM is based on a hexapod architecture that ensures both thermal decoupling and mechanical robustness during launch. In this paper, we present the characterization of its thermal and mechanical performances. A dedicated experimental setup was used to investigate the thermal behavior of the STM across a broad temperature range. The study reveals limitations of the collar design, with incomplete power interception from thermal boundary resistances and vibration test failure traced to defective strut gluing. These results guide the next STM iteration with optimized collar and strut assembly for reliable CCDR operation in space.

astro-ph.IM

The Simons Observatory: Development of a Pipeline to Detect Rapid Transients in Time-Ordered Data

We introduce a method for detecting astrophysical transients evolving on timescales of milliseconds to minutes using cosmic microwave background (CMB) survey telescopes. While previous transient searches in CMB data operate in map space, our pipeline directly processes the raw time-ordered data, enabling sensitivity to fast, dynamic signals. We integrate our detection approach into the Simons Observatory time-domain pipeline and assess the performance by injecting symmetric, stellar flare-like light curves into simulated observations. For events flaring with a timescale of 0.5 s, the pipeline detects $\gtrsim90$ % of events at flux densities of 800, 1150, 1650, and 4250\,mJy when measured in the 93, 145, 225, and 280 GHz bands respectively. At a fixed peak flux density, the pipeline more readily detects longer flares. The limiting flux density for 90 % completeness is four times lower for a $\ge5$ s flare than for a 0.5 s flare, while the flux density limits for $\gtrsim50$ % detection efficiency are comparable to the rms noise of the time-ordered data. We are able to determine the position of detected events in each observing band, with a positional uncertainty at the detection threshold comparable to the telescope resolution at that band. These results demonstrate the readiness of this pipeline for incorporation into upcoming Simons Observatory data analyses.

astro-ph.IM

Thermal conductivity of various CFRPs from 100 mK to 20 K

Carbon-fiber-reinforced polymers (CFRPs) are some of the most useful materials for building spacecraft and aerospace tools. They are especially valuable for systems that work at extremely cold (cryogenic) temperatures because they are strong, lightweight, and don't transfer heat easily. In this study, researchers measured how well heat moves through several different types of carbon fiber samples, specifically T300, T700, HS40, M55J, and IMA, at different fiber layouts and densities. These measurements were taken at ultra-cold temperatures ranging from 100 mK to 20 K. The team used a newly developed analysis method to calculate the thermal conductivity for each sample. Finally, they shared how each material behaved at different temperatures and compared their findings to previous research.

astro-ph.IM