Search arXivSearch

arXiv · 2505.03395

A chemically etched D-band waveguide orthomode transducer for CMB measurements

Abstract

This study presents a prototype D-band waveguide orthomode transducer (OMT) fabricated using chemically etched brass platelets. This method offers a fast, cost-effective, and scalable approach for producing waveguide OMTs above 100 GHz, making it well-suited for current and future Cosmic Microwave Background polarization experiments, where large focal planes with thousands of receivers are required to detect the faint primordial \textit{B}-modes. Chemical etching has already demonstrated its effectiveness in manufacturing corrugated feedhorn arrays with state-of-the-art performance up to 150 GHz. Here, we evaluate its applicability to more complex structures, such as OMTs. We designed a single OMT prototype operating in the 130-170 GHz range, fabricated by chemically etching 0.15 mm-thick brass plates, which were then stacked, aligned, and mechanically clamped. Simulations based on metrological measurements of the OMT profile predict return losses below $-$10 dB, isolation better than $-$30 dB, and transmission around $-$0.5 dB. The measured transmission and isolation, however, is around $-$1.5/$-$2 dB and $<-$20 dB, respectively. Further simulations show that the degradation in the transmission is related to defects and roughness along the etched profile ($\mathrm{RMS}\simeq$3 $μ$m), which is a typical and unavoidable effect of chemical etching. The discrepancy in isolation, instead, could arise from a slight rotation ($\sim$3$^{\circ}$) of the polarization angle within the measurement chain. Our results show that chemical etching is a fast, low-cost, and scalable technique for producing waveguide OMTs with state-of-the-art performance in terms of return loss and isolation. However, at frequencies above 100 GHz the transmission coefficient may degrade due to the mechanical precision limitations of chemical etching.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E. Manzan, A. Mennella, F. Cavaliere, C. Franceschet, S. Mandelli, F. Montonati, M. Zannoni, P. de Bernardis, M. Bersanelli, E. Boria, N. Brancadori, A. Coppolecchia, M. Gervasi, L. Lamagna, A. Limonta, S. Masi, A. Paiella, A. Passerini, F. Pezzotta, G. Pettinari, F. Piacentini, E. Tommasi, D. Viganò, A. Volpe. 2025-05-06. A chemically etched D-band waveguide orthomode transducer for CMB measurements. https://arxiv.org/abs/2505.03395

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Performance characterization of a new Structural and Thermal Architecture for a future spaceborne Closed-Cycle Dilution Refrigerator

A Structural and Thermal Model (STM) has been developed to support the new spaceborne Closed-Cycle Dilution Refrigerator (CCDR), which aims to provide continuous cooling at 100~mK for long-duration astrophysical missions. The STM is based on a hexapod architecture that ensures both thermal decoupling and mechanical robustness during launch. In this paper, we present the characterization of its thermal and mechanical performances. A dedicated experimental setup was used to investigate the thermal behavior of the STM across a broad temperature range. The study reveals limitations of the collar design, with incomplete power interception from thermal boundary resistances and vibration test failure traced to defective strut gluing. These results guide the next STM iteration with optimized collar and strut assembly for reliable CCDR operation in space.

astro-ph.IM

The Simons Observatory: Development of a Pipeline to Detect Rapid Transients in Time-Ordered Data

We introduce a method for detecting astrophysical transients evolving on timescales of milliseconds to minutes using cosmic microwave background (CMB) survey telescopes. While previous transient searches in CMB data operate in map space, our pipeline directly processes the raw time-ordered data, enabling sensitivity to fast, dynamic signals. We integrate our detection approach into the Simons Observatory time-domain pipeline and assess the performance by injecting symmetric, stellar flare-like light curves into simulated observations. For events flaring with a timescale of 0.5 s, the pipeline detects $\gtrsim90$ % of events at flux densities of 800, 1150, 1650, and 4250\,mJy when measured in the 93, 145, 225, and 280 GHz bands respectively. At a fixed peak flux density, the pipeline more readily detects longer flares. The limiting flux density for 90 % completeness is four times lower for a $\ge5$ s flare than for a 0.5 s flare, while the flux density limits for $\gtrsim50$ % detection efficiency are comparable to the rms noise of the time-ordered data. We are able to determine the position of detected events in each observing band, with a positional uncertainty at the detection threshold comparable to the telescope resolution at that band. These results demonstrate the readiness of this pipeline for incorporation into upcoming Simons Observatory data analyses.

astro-ph.IM

Thermal conductivity of various CFRPs from 100 mK to 20 K

Carbon-fiber-reinforced polymers (CFRPs) are some of the most useful materials for building spacecraft and aerospace tools. They are especially valuable for systems that work at extremely cold (cryogenic) temperatures because they are strong, lightweight, and don't transfer heat easily. In this study, researchers measured how well heat moves through several different types of carbon fiber samples, specifically T300, T700, HS40, M55J, and IMA, at different fiber layouts and densities. These measurements were taken at ultra-cold temperatures ranging from 100 mK to 20 K. The team used a newly developed analysis method to calculate the thermal conductivity for each sample. Finally, they shared how each material behaved at different temperatures and compared their findings to previous research.

astro-ph.IM