Search arXivSearch

arXiv · 2505.05144

Output correction factors in a 1.5 T magnetic field determined at the central axis and at the lateral dose maximum for five detectors using alanine

Abstract

In recent literature, the output correction factor in a 1.5T magnetic field, kB,Q,Clin, were determined only for the central axis (CAX), including our last work. At an MR-linac, the determination of the CAX position relies on e.g. MV-imaging and is at small field sizes located at the penumbra, whereas the maximum of the lateral profile (MAX) position is directly measurable. This study determined kB,Q,Ratio - the influence of the magnetic field on the output correction factor without a magnetic field, kQ,Clin - and kB,Q,Clin for both CAX and MAX fully experimentally for two MR-optimized ionization chambers, their conventional counterparts, and a solid-state detector. Additionally, the uncertainty due to intra-type variation for tabulated kB,Q,Clin was estimated. Measurements were conducted using an experimental setup consisting of a mobile electromagnet positioned in front of a standard clinical linac (6MV, 1.5T). Intra-type variation for the solid-state detector was assessed using 4 detectors. The change of absorbed dose to water was determined with alanine. Within the uncertainty, no difference in kB,Q,Ratio was observed between the MR-optimized chambers and their conventional counterparts. For the solid-state detector, no difference between CAX and MAX was observed. For all detectors, kB,Q,Clin remained constant down to a field size of 2.5x2.5cm2. At smaller field sizes, for MAX and for all detectors, kB,Q,Ratio decreased linearly. The maximum intra-type variation standard uncertainty was 0.009 for the smallest field size, with and without a magnetic field. In summary, kB,Q,Ratio and kB,Q,Clin, including its uncertainty, was successfully determined for five detectors at both CAX and MAX. For ionization chambers, kB,Q,Clin is lower at MAX, whereas for the solid-state detector, it remains the same. For the tabulated correction factors uncertainty, intra-type variation must be considered.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Stephan Frick, Daniela Thorwarth, Thomas Hackel, Ralf-Peter Kapsch. 2025-05-19. Output correction factors in a 1.5 T magnetic field determined at the central axis and at the lateral dose maximum for five detectors using alanine. https://arxiv.org/abs/2505.05144

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Prediction of biological radiation effects based on ionization clusters (nanodosimetry)

This article reviews approaches that link the formation of ionization clusters in nanometric volumes to radiobiological effectiveness. The corresponding models were developed as the field of nanodosimetry developed. Some address early biological radiation effects, such as DNA damage, while most aim to predict cell survival or inactivation. The models also differ in the nanodosimetric quantities considered, with many based on the probability distribution of ionization cluster formation in a single target. Some models account for the synergistic effects of pairs of ionization clusters formed in different targets. Several models feature macroscopic aggregation frameworks based on particle fluence, which are proposed for use in radiotherapy treatment planning, particularly in ion-beam radiotherapy. The models are presented here using harmonized terminology and notation for nanodosimetric quantities. An extension of the conceptual framework of nanodosimetry is also discussed. This extension transitions from a target-centered description to a track-centered description. It also introduces nanodosimetry-based analogs of dosimetric concepts, such as dose and linear energy transfer. This paper traces and summarizes the historical development of nanodosimetry-based biological effect models and discusses conceptual aspects of the models to reveal their underlying assumptions and the extent to which they are mechanistic or merely elucidate correlations. Eventually, an attempt is made to identify the key open questions in this field that still need to be addressed.

physics.med-ph

Contextual Cellular Growth (ConCeG) of neural cells for realistic grey matter tissue generation for diffusion MRI simulations

Accurate interpretation of diffusion magnetic resonance imaging (dMRI) signals in grey matter (GM) remains challenging due to the complex, heterogeneous, and densely packed cellular environment. Numerical phantoms provide a controlled framework for investigating the relationship between microstructure and diffusion signals, yet existing approaches often lack the morphological realism and multi-cellular organisation required to faithfully represent GM tissue. In this work, we introduce Contextual Cellular Growth (ConCeG), a generative framework for creating individual cells or constructing dense, three-dimensional, multi-cellular GM substrates informed by real neuronal and glial morphologies. The method combines topological neuron synthesis with a spatially constrained growth network, allowing for the controlled generation of heterogeneous cellular environments with realistic intra- and extracellular compartments. Synthetic cells are generated using morphological and topological characteristics derived from biological reconstructions. We validate the framework through comparisons of structural features with real cellular data, demonstrating strong agreement in branch order, length, angle, and tortuosity distributions. Power spectrum analysis further shows that both intracellular compartments reproduce the spatial correlations observed in biological tissue. Together, these results show ConCeG provides a biologically grounded framework for generating grey matter substrates suitable for large scale diffusion MRI simulation.

physics.med-ph

Magnetic Field of Firing Neuron in Humans: Measurable by Quantum Sensing MRI?

Firing neurons generate action potentials that propagate along axons to transmit signals supporting cognitive functions. These electrical currents generate magnetic fields, yet direct detection of these neuronal magnetic fields by MRI remains elusive. This Mini Review investigates why this goal has been proven difficult to achieve and whether an emerging approach, quantum sensing MRI, can overcome the challenge.

physics.med-ph