Search arXivSearch

arXiv · 2505.07010

Results from a 2nd production run of low temperature wafer-wafer bonded pad-diodes for particle detection

Abstract

We are investigating the use of low temperature wafer-wafer bonding in the fabrication of next-generation particle pixel detectors. This bonding technique could enable the integration of fully processed CMOS readout wafers with high-Z absorber materials, facilitating the creation of highly efficient X-ray imaging detectors. It might also facilitate the integration of structures embedded inside the wafer bulk, such as deep uniform gain layers. The bonding process results in a thin (nm-scale) amorphous layer at the bonding interface. To study the impact of this interface on detector operation, we fabricated simple wafer-wafer bonded pad diodes using high resistivity float-zone silicon wafers. Results from a first fabrication run of such diodes revealed that the presence of the bonding interface alters the depletion behaviour, with the interface acting as a heavily doped N++ layer. However, metal contamination of the bonding surfaces during fabrication compromised these results, making them unrepresentative of an ideal bonding interface. In this paper we present the results from a subsequent fabrication run, which does not exhibit this sort of metal contamination. These results confirm that the bonding interface behaves as a heavily doped N++ layer, even without contamination. Further, we discuss the reverse leakage current of the bonded samples, where current vs. voltage measurements show a behaviour which is consistent with current generated within the depletion region of the samples.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J. Wüthrich, K. Deplazes, A. Rubbia. 2025-06-16. Results from a 2nd production run of low temperature wafer-wafer bonded pad-diodes for particle detection. https://arxiv.org/abs/2505.07010

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det