Search arXivSearch

arXiv · 2505.12798

Dynamic stall reattachment revisited

Abstract

Dynamic stall on airfoils is an undesirable and potentially dangerous phenomenon. The motto for aerodynamic systems with unsteadily moving wings, such as helicopters or wind turbines, is that prevention beats recovery. In case prevention fails or is not feasible, we need to know when recovery starts, how long it takes, and how we can improve it. This study revisits dynamic stall reattachment to identify the sequence of events during flow and load recovery and to characterise key observable features in the pressure, force, and flow field. Our analysis is based on time-resolved velocity field and surface pressure data obtained experimentally for a two-dimensional, sinusoidally pitching thin airfoil. Stall recovery is a transient process that does not start immediately when the angle of attack falls below the critical stall angle. The onset of recovery is delayed to angles below the critical stall angle and the duration of the reattachment delay decreases with increasing unsteadiness of the pitching motion. An angle of attack below the critical angle is a necessary, but not sufficient condition to initiate the stall recovery process. We identified a critical value of the leading-edge suction parameter, independent of the pitch rate, that is a threshold beyond which reattachment consistently initiates. Based on prominent changes in the evolution of the shear layer, the leading-edge suction, and the lift deficit due to stall, we divided the reattachment process into three stages: the reaction delay, wave propagation, and the relaxation stage, and extracted the characteristic features and time-scales for each stage.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Sahar Rezapour, Karen Mulleners. 2026-01-16. Dynamic stall reattachment revisited. https://doi.org/10.1017/jfm.2026.11228

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Mathematical modeling on peristaltic flow of a Prandtl fluid with effects of slip conditions and inclined magnetic field

The manuscript provides a description of a theoretical analysis of a non-Newtonian Prandtl fluid subject to peristaltic flow through an inclined asymmetric channel. We explore the effect of an inclined magnetic field on the peristaltic flow. This is relevant for applications involving fluid flow in narrow, inclined (tilted) tubes similar to blood vessels or the digestive system. The model also includes thermodynamic aspects such as heat diffusion (the Soret effect) and viscous dissipation resulting from wall-fluid slip conditions, which may help optimize medical devices such as lab-on-a-chip systems and dialysis machines. In this study, the concentration of a generic chemical, temperature, and fluid velocity are taken into account through mass, heat, and momentum balances, respectively. The solution is approximated using numerical techniques suitable for long wavelengths (low frequency) and low Reynolds numbers. The study also discusses trapping phenomena, which are crucial from a clinical point of view. The developed insights can improve the understanding of physiological flows in the gastrointestinal tract and blood vessels. By understanding how the fluid moves and how particles are trapped, these insights may contribute to the design of improved medical pumps and artificial organs. Graphical visualizations are provided for the fluid velocity profile, temperature distribution, and concentration of a generic chemical. Furthermore, the numerical results are validated through comparison with a closed-form solution from a benchmark problem.

physics.flu-dyn

Discovery of a dispersion model at high Peclet numbers

Peclet number characterises the transition from classical Taylor-Aris dispersion to convection-dominated longitudinal solute transport, with the classical model becoming inadequate at extremely high radial Peclet number $Pe_r$. We develop a novel explicit-closure one-dimensional (1-D) effective dispersion model for this high-$Pe_r$ regime by introducing two closure coefficients, $θ_u$ and $θ_d$, whose functional structures are identified using low-frequency transfer-function matching and a modified Kolmogorov-Arnold network (KAN). The resulting model captures the transition from classical Taylor-Aris dispersion at low $Pe_r$ to convection-dominated dispersion at high $Pe_r$. Analysis reveals that, in the high-$Pe_r$ regime, axial transport is redistributed between the effective convection flux and the dispersive flux, resulting in a reduced macroscopic convection velocity. Numerical validation demonstrates close agreement with the convection-diffusion model over the investigated high-$Pe_r$ conditions, while the classical Taylor-Aris model exhibits substantial deviations. Application of the proposed model to averaged flow velocity inversion further demonstrates improved velocity estimation, particularly in the high-$Pe_r$ regime. These results highlight the importance of accounting for non-classical dispersion for reliable contrast-agent-based arterial blood flow velocimetry and provide new insight into high-$Pe_r$ mass transport.

physics.flu-dyn

Optimization of fluid mixing by reinforcement learning using limit cycles of a dynamical system

We propose a method to overcome the difficulties encountered when applying reinforcement learning to fluid mixing processes. The proposed method has two main features: (i) it does not require detailed measurements of the flow state, and (ii) by effectively exploiting a stable limit cycle of a two-dimensional dynamical system (the Li'enard system), it can stably perform optimization without imposing explicit constraints on the control parameters. As an illustrative example, we optimize a process in which a fluid contained in a cylindrical vessel is mixed by periodically rotating the vessel. The resulting optimal vessel motion is physically reasonable: it reverses its direction of rotation before a solid-body rotation state is established. Furthermore, even when the fluid viscosity increases with time during the mixing process, the method can continuously adapt the control parameters to the changing viscosity.

physics.flu-dyn