Search arXivSearch

arXiv · 2505.16669

An open harmonic chain: Exact vs global and local reduced dynamics

Abstract

In the following, we study the dissipative time-evolution of a quantum chain consisting of three coupled harmonic oscillators, the first and third of which weakly interact quadratically with two independent thermal baths in equilibrium at different temperatures. Due to the quadratic form of the total Hamiltonian, the unitary dynamics of the compound system is formally analytically solvable and defines a one-parameter group of Gaussian maps which enables us to solve the exact dynamics of the chain numerically. Following the Gorini-Kossakowski-Sudarshan-Lindblad (GKSL) approach to open quantum systems, one can perform the rotating wave approximation with respect to the interacting, or non-interacting chain Hamiltonian and respectively derive the so-called global and local master equations. The solutions of the ensuing different master equations can then be compared with the exact one, possibly sorting out the two approaches in correspondence to different time-scales of the system. We derive the steady states of the open chain quantum dynamics in the two approaches and show that the behaviour of fidelity between them versus inter-oscillator coupling depends on the two bath temperatures, revealing the existence of a temperature-dependent critical inter-oscillator coupling strength that determines the domain of validity of each approach. When the newly found coupling is less than this critical value, the local approach outperforms the global approach, whereas for larger inter-oscillator coupling, the global approach is a better approximation of the exact evolution. This critical value of inter-oscillator coupling depends on the two bath temperatures, which then play a crucial role in deciding the best possible approximating open dynamics.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Melika Babakan, Fabio Benatti, Laleh Memarzadeh. 2025-05-22. An open harmonic chain: Exact vs global and local reduced dynamics. https://arxiv.org/abs/2505.16669

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Iteratively decoded magic state distillation

We present numerical simulation results for the 7-to-1 and 15-to-1 state distillation circuits, constructed using transversal CNOTs acting on multiple surface code patches. The distillation circuits are decoded iteratively using the method outlined in [arXiv:2407.20976]. We show that, with a re-configurable qubit architecture, we can perform fast magic state distillation in $\sim\mathcal{O}(1)$ code cycles. We confirm that both circuits suppress an injected input logical error rate $p$ to $\mathcal{O}(p^3)$ in the presence of additional circuit-level noise. This is done with two types of stabiliser proxies, distilling logical $|-\rangle$ and $|Y\rangle$ states, the latter is the intended state of the 7-to-1 circuit while a stabiliser-proxy for the 15-to-1 circuit. We then also provide numerical evidences for actual $|T\rangle$ state distillation using the 15-to-1 circuit with a faulty-$T$ measurement, leveraging recent near-Clifford simulation tools. Finally, we outline how ZX-calculus and Pauli webs can be used to benchmark stabiliser proxies for these distillation circuits.

quant-ph

Enhanced measurements on quantum computers via the simultaneous probing of non-commuting Pauli operators

Measuring the state of quantum computers is a highly non-trivial task, with implications for virtually all quantum algorithms. A promising avenue is multi-copy schemes, where identical copies of a quantum state are measured jointly so that all Pauli operators within the considered observable can be simultaneously assessed. Here, we present a first implementation of such a two-copy scheme in a measurement protocol. Based on Bayesian statistics, it accurately estimates not only the average of the desired observable but also the error en route. This enables an adaptive shot-allocation algorithm that preferentially samples the most uncertain Pauli terms. In regimes with many non-commuting Pauli operators, this ``double'' scheme can outperform the state-of-the-art measurement protocol in minimizing total shots for a given precision. We also numerically confirm the finding in previous theoretical works that the two-copy scheme incurs an overhead due to the square-root relationship between the variance of measured quantities and the number of measurement shots.

quant-ph

Thermodynamics of a phaseonium-driven optomechanical Otto engine

We study an optomechanical Otto engine whose working medium is a single-mode cavity driven by beams of coherently prepared three-level phaseonium atoms. The atoms are not thermal reservoirs in the Gibbs sense; rather, their populations and ground-state coherence set the detailed-balance ratio of the cavity collision map, so that the field relaxes to a Gibbs state at an operational apparent temperature. We combine the finite-time collision-model dynamics with radiation-pressure work extraction and compare three reservoir preparations: a thermal reference at the same apparent temperatures, an incoherent atomic beam with the same populations, and the coherent phaseonium beam. We show that the phaseonium isochore charges the cavity passively: the cavity ergotropy and energy-basis coherence remain zero up to numerical precision, while the state converges to the Gibbs fixed point selected by the apparent detailed balance. We further estimate lower bounds on the cost of preparing the atomic populations and coherence, showing that the relevant advantage of phaseonium is a resource-preparation tradeoff rather than a cost-free enhancement over a thermal bath at the same temperature. Finally, we assess the finite-time performance of a two-cavity cascade with additive mechanical work accounting. Over the investigated coherence-phase range, the cascade produces approximately $47\%$--$52\%$ more power than the single-cavity engine while requiring only $65\%$--$68\%$ of the hot and cold phaseonium atoms needed by two independent engines, resulting in a $9\%$--$15\%$ enhancement of power per injected atom over a complete cycle.

quant-ph