Search arXivSearch

arXiv · 2505.18851

Muon Imaging for Illicit Cargo Detection: A Simulation-Based Study

Abstract

This study evaluates the potential of muon tomography as a non-invasive technique for detecting concealed illicit drugs in cargo, based on detailed simulations performed using the GEANT4 toolkit. A combined analysis of muon scattering and absorption data was employed to enhance material discrimination, with a focus on realistic smuggling scenarios involving cocaine hidden within legitimate cargo. A two-stage inspection protocol is proposed to balance detection speed and resolution. In the first stage, a rapid scan lasting ~ 60 seconds is used to identify anomalous scattering and absorption rates, without requiring full tomographic reconstruction. Receiver Operating Characteristic (ROC) analysis of rapid scan data revealed that the Random Forest classifier achieved an area under the curve (AUC) of 0.9969, while the multivariate normal likelihood model attained an AUC of 0.9977, both indicating excellent discrimination between benign cargo and smuggled contraband. Upon detection of anomalies, an extended scan ~30 minutes is initiated to enable high-resolution three-dimensional imaging for accurate localization and identification of hidden materials. Simulation results demonstrate that, with a detector spatial resolution of 1~mm (FWHM), concealed contraband such as cocaine can be detected with approximately 3 sigma statistical significance during the rapid scan phase. In extended scans, cocaine packages concealed within banana boxes were successfully visualized and automatically identified using clustering algorithms such as DBSCAN applied to the tomographic reconstruction. These findings confirm the feasibility of cosmic-ray muon tomography as a passive, safe, and effective approach for contraband detection in real-world cargo inspection applications.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Anzori Sh. Georgadze. 2025-06-02. Muon Imaging for Illicit Cargo Detection: A Simulation-Based Study. https://arxiv.org/abs/2505.18851

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det