Search arXivSearch

arXiv · 2505.23050

A Silicon Microstrip Detector for Power-Limited and Large Sensitive Area Applications

Abstract

A silicon microstrip detector (SSD) has been developed to have state of the art spatial resolution and a large sensitive area under stringent power constraints. The design incorporates three floating strips with their bias resistors inserted between two aluminum readout strips. Beam test measurements with the single sensor confirmed that this configuration achieves a total detection efficiency of $99.8 \, \%$ and spatial resolution $7.6 \, \mathrm{μm}$ for MIPs. A double-$η$ algorithm was developed to optimize hit position reconstruction for this SSD. The design can be adapted for large area silicon detectors.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Dexing Miao, Zijun Xu, Zhiyu Xiang, Pingcheng Liu, Giovanni Ambrosi, Mattia Barbanera, Mengke Cai, Xudong Cai, Hsin-Yi Chou, Matteo Duranti, Valerio Formato, Maria Ionica, Yaozu Jiang, Liangchenglong Jin, Vladimir Koutsenko, Qinze Li, Cong Liu, Xingjian Lv, Alberto Oliva, Wenxi Peng, Rui Qiao, Gianluigi Silvestre, Zibing Wu, Xuhao Yuan, Hongyu Zhang, Xiyuan Zhang, Jianchun Wang. 2025-05-29. A Silicon Microstrip Detector for Power-Limited and Large Sensitive Area Applications. https://arxiv.org/abs/2505.23050

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det