Search arXivSearch

arXiv · 2506.05553

Investigation of Neoclassical Tearing Mode Detection by ECE Radiometry in Tokamak Reactors via Asymptotic Matching Techniques

Abstract

The TJ toroidal tearing mode code is used to make realistic predictions of the electron cyclotron emission (ECE) signals generated by neoclassical tearing modes (NTMs) in an ITER-like tokamak plasma equilibrium. In the so-called "outer region'', which comprises the bulk of the plasma, helical harmonics of the magnetic field with the same toroidal mode number as the NTM, but different poloidal mode numbers, are coupled together by the Shafranov shifts and shaping of the equilibrium magnetic flux-surfaces. In the "inner region'', which is localized in the vicinity of the NTM rational surface, helical harmonics whose poloidal and toroidal mode numbers are in the same ratio as those of the NTM are coupled together nonlinearly to produce a radially asymmetric magnetic island chain. The solutions in the inner and outer regions are asymptotically matched to one another. The asymptotic matching process determines the overall magnetic structure of the NTM, as well as the global perturbation to the electron temperature caused by the mode. A simulated ECE diagnostic is developed that accounts for the downshifting and broadening in frequency of the signal due to the relativistic mass increase of the emitting electrons.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R. Fitzpatrick. 2025-07-28. Investigation of Neoclassical Tearing Mode Detection by ECE Radiometry in Tokamak Reactors via Asymptotic Matching Techniques. https://arxiv.org/abs/2506.05553

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Experimental validation of a fast control-oriented, physics-informed surrogate model for plasma equilibrium reconstruction in the TCV tokamak

Magnetic equilibrium reconstruction provides the plasma state estimate required for real-time shape control in tokamaks. We present a fast, physics-informed neural network surrogate of the \texttt{liuqe} equilibrium reconstruction code \cite{liuqe1} for the TCV tokamak at EPFL, achieving inference times below 100~$\bmμ$s and enabling 10~kHz shape control. The model is trained on around 10,000 TCV discharges spanning the full operational range of plasma shapes. Its modular branch/trunk architecture decouples magnetic measurement encoding from spatial coordinate processing, enabling physics-informed regularization via automatic differentiation of the predicted flux map. The surrogate has been compiled and deployed on the TCV real-time control system, and validated both offline and in real time against the models \texttt{liuqe-rt} and \texttt{lih}, showing comparable accuracy. Closed-loop performance assessed with the real-time software in-the-loop \texttt{fge} \cite{fge1} demonstrates control-equivalent behavior across multiple control strategies.

physics.plasm-ph

Development of Thomson parabola spectrometer for diagnostics of ions driven by ultrahigh intensity laser: Simulations and numerical analysis

A Thomson parabola ion spectrometer (TPIS) has been designed and developed for diagnostics of laseraccelerated ion beams in the MeV energy range. The TPIS has been validated by ion acceleration experiment at petawatt laser facility. Necessary simulations to evaluate the electric and magnetic field distributions have been performed with the help of a numerical simulation software to aid the selection of the spectrometer geometry while minimising fringe-field effects. Analytical dispersion expressions have been formulated from the simulations that take into account the spatial variation in the electromagnetic field profiles. The ion deflections obtained from these expressions demonstrate an improved agreement with experimentally measured proton trajectories compared to the case when constant fields are considered. The TPIS hence fabricated in-house has been subject to magnetic field measurements, which are in excellent agreement with the simulated field profile. The TPIS has the provision to change the field-free drift region, showcasing flexibility to be employed over a broad energy range and with different experimental setups. The spectrometer has been subsequently used for detecting laser-accelerated ion beams from thin aluminum foil targets. These experiments have demonstrated the capability of the spectrometer to resolve multiple ion species with sufficient separation between them. The developed TPIS provides a compact, flexible and accurate diagnostic for high-energy laser-plasma experiments.

physics.plasm-ph

Calibration of cross-field transport models in SOLPS-ITER on the TCV-X21 case

Cross-field turbulent transport remains one of the largest uncertainties in edge plasma simulations and is commonly approximated through empirical transport coefficients. In this work, we calibrate and assess several cross-field transport models implemented in SOLPS-ITER using measurements from the TCV-X21 reference case. The considered models range from conventional constant-diffusivity descriptions to the self-consistent k-model, in which anomalous diffusivities evolve along with plasma conditions. Model parameters are estimated through gradient-based optimization by minimizing discrepancies between simulated and experimental upstream and divertor profiles in forward field configuration. The calibration results show that increasing the number of free parameters substantially improves agreement with the calibration dataset. However, these more flexible models exhibit poor predictive capability when applied to the reversed field configuration, indicating overfitting. In contrast, the simplest constant-diffusivity model provides the best overall predictive performance while requiring only a small number of calibrated parameters. The k-model achieves a calibration quality comparable to the constant-diffusivity model and reproduces the experimental profiles with similar accuracy, while simultaneously providing a physics-based description of the spatial variation of anomalous transport. Predictions for a density scan reveal differences that are not apparent near the calibration point. The k-model predicts increasing transport levels around the separatrix with increasing density, leading to broader upstream profiles and an earlier onset of divertor rollover compared to the constant-diffusivity model. The presented framework provides a systematic and efficient route for model calibration in SOLPS-ITER, and a set of calibrated k-model parameters to be employed in future studies.

physics.plasm-ph