Search arXivSearch

arXiv · 2506.08974

Diver-Robot Communication Dataset for Underwater Hand Gesture Recognition

Abstract

In this paper, we present a dataset of diving gesture images used for human-robot interaction underwater. By offering this open access dataset, the paper aims at investigating the potential of using visual detection of diving gestures from an autonomous underwater vehicle (AUV) as a form of communication with a human diver. In addition to the image recording, the same dataset was recorded using a smart gesture recognition glove. The glove uses elastomer sensors and on-board processing to determine the selected gesture and transmit the command associated with the gesture to the AUV via acoustics. Although this method can be used under different visibility conditions and even without line of sight, it introduces a communication delay required for the acoustic transmission of the gesture command. To compare efficiency, the glove was equipped with visual markers proposed in a gesture-based language called CADDIAN and recorded with an underwater camera in parallel to the glove's onboard recognition process. The dataset contains over 30,000 underwater frames of nearly 900 individual gestures annotated in corresponding snippet folders. The dataset was recorded in a balanced ratio with five different divers in sea and five different divers in pool conditions, with gestures recorded at 1, 2 and 3 metres from the camera. The glove gesture recognition statistics are reported in terms of average diver reaction time, average time taken to perform a gesture, recognition success rate, transmission times and more. The dataset presented should provide a good baseline for comparing the performance of state of the art visual diving gesture recognition techniques under different visibility conditions.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Igor Kvasić, Derek Orbaugh Antillon, Ðula Nađ, Christopher Walker, Iain Anderson, Nikola Mišković. 2025-06-10. Diver-Robot Communication Dataset for Underwater Hand Gesture Recognition. https://doi.org/10.1016/j.comnet.2024.110392

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

KELP: K-space-conditioned Estimation of Learned Sampling Patterns for Scan-Adaptive Multi-Coil MRI

Deep learning techniques have gained considerable attention for accelerating MRI acquisition while maintaining image quality. In this work, we present a convolutional neural network (CNN)-based framework for predicting scan-adaptive undersampling patterns directly from low-frequency multi-coil $k$-space data. Unlike approaches that optimize sampling patterns during training or rely on nearest-neighbor search at inference, our method is trained using precomputed scan-adaptive optimized masks as supervised labels and predicts a scan-specific sampling pattern in a single forward pass. The training procedure alternates between optimizing the sampling network and a reconstruction network, allowing the learned masks to adapt to reconstruction performance. Experiments on the fastMRI multi-coil knee dataset demonstrate competitive reconstruction quality compared with existing population- and scan-adaptive sampling approaches at $4\times$ and $8\times$ acceleration factors. In addition, the proposed method enables efficient scan-specific mask prediction with inference cost independent of the training dictionary size.

eess.IV

LaminoDiff: Generative Computed Laminography via Near-Isotropic Spectral Supervision and Anisotropic Geometry

Computed Laminography (CL) is widely used for nondestructive inspection of extended planar objects, but its restricted angular coverage produces an anisotropic point spread function, missing-cone spectral incompleteness, and severe aliasing with interlayer leakage. This paper presents LaminoDiff, a physics-constrained diffusion framework for CL reconstruction. During training, a CT-derived near-isotropic supervision target is reconstructed from full-angle Computed Tomography (CT) projections physically degraded to match CL detector noise and focal-spot blur while retaining full angular coverage; it is withheld from inference. At inference, the reverse process uses only the CL observation. An Anisotropic Representation (AR) constructs depth-aware channels from three adjacent slices: a neighbor average, a center-neighbor residual, and the retained current slice, followed by directional in-plane feature extraction. Experiments on simulated and real multilayer printed circuit board data, including ball grid array and high-frequency stub samples, show that LaminoDiff improves artifact suppression, edge preservation, and depth stratification over analytic Feldkamp--Davis--Kress and representative learning-based baselines.

eess.IV

IViT: A Novel Interpretable Visual Transformer for Skin Disease Detection

The clinical diagnosis of skin diseases is susceptible to interference from inter-class similarity of skin lesions, and over-reliance on clinicians'experience easily leads to subjective bias. Although existing deep learning aided diagnosis methods achieve competitive accuracy, they suffer from the black-box opacity of Vision Transformer (ViT) and poor adaptability to medical few-shot scenarios. Moreover, mainstream explainable algorithms generally face the bottleneck of significant accuracy degradation when improving interpretability. This paper proposes an interpretable ViT (IViT) constrained by Quadratic Programming (QP). The introduced pre-trained transfer learning adapts to few-shot feature extraction. A discrete QP feature selection framework is constructed to screen generic and discriminative features consistent with clinical diagnostic logic. A multi-objective loss function is designed to reduce feature redundancy and optimize activation distribution while preserving classification performance. Experimental results on six standard skin disease datasets show that IViT achieves an accuracy of 93.80%, only 0.21% lower than the baseline, with feature redundancy reduced by 29.5%. Its core activation regions are consistent with clinically concerned lesion areas. The proposed model balances accuracy and interpretability, providing a reliable solution for the clinical deployment of few-shot intelligent skin disease diagnosis.

eess.IV