Search arXivSearch

arXiv · 2506.10858

Med-URWKV†: Toward Enhanced Pretrained Pure VRWKV Models for Medical Image Segmentation

Abstract

Medical image segmentation is a fundamental task in computer-aided diagnosis and treatment. Existing approaches based on CNNs, ViTs, Mamba, and hybrid models still suffer from limitations such as restricted receptive fields, high computational cost, or insufficient accuracy. Recently, Vision Receptive-field Weighted Key-Value (VRWKV) models have emerged as a promising alternative,delivering strong long-range dependency modeling for visual tasks. However, current studies on VRWKV-based medical image segmentation mainly focus on hybrid architectures trained from scratch, while the potential of large-scale pretrained pure VRWKV models remains unexplored. In this work, we systematically investigate the effectiveness of pure VRWKV architectures for medical image segmentation. We construct Med-URWKV-T and Med-URWKV-S by reusing pretrained VRWKV encoders at different scales and pairing them with pure VRWKV decoders, enabling a comprehensive evaluation of pretrained pure VRWKV models in this domain. To further enhance performance, we propose two VRWKV-compatible modules: a Frequency-Aware Wavelet Attention (FAWA) module, which exploits wavelet transforms to capture edge details and structural characteristics, and a Multi-Scale Channel Fusion (MSCF) module, which integrates multi-scale features to strengthen informative channel representations. By incorporating them into Med-URWKV-T, we obtain the enhanced model Med-URWKV†. Extensive experiments on five medical image segmentation datasets demonstrate that Med-URWKV achieves performance comparable to or superior to state-of-the-art methods and carefully designed hybrid VRWKV architectures. Moreover, Med-URWKV† further improves segmentation accuracy, surpassing Med-URWKV-S while using only half of its parameter count, and achieves the highest average Dice similarity coefficient of 88.00%. The codes will be released.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Zhenhuan Zhou, Yining Li, Yanlin Wu, Haohan Zou, Yan Wang, Tao Li. 2026-05-30. Med-URWKV†: Toward Enhanced Pretrained Pure VRWKV Models for Medical Image Segmentation. https://arxiv.org/abs/2506.10858

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

KELP: K-space-conditioned Estimation of Learned Sampling Patterns for Scan-Adaptive Multi-Coil MRI

Deep learning techniques have gained considerable attention for accelerating MRI acquisition while maintaining image quality. In this work, we present a convolutional neural network (CNN)-based framework for predicting scan-adaptive undersampling patterns directly from low-frequency multi-coil $k$-space data. Unlike approaches that optimize sampling patterns during training or rely on nearest-neighbor search at inference, our method is trained using precomputed scan-adaptive optimized masks as supervised labels and predicts a scan-specific sampling pattern in a single forward pass. The training procedure alternates between optimizing the sampling network and a reconstruction network, allowing the learned masks to adapt to reconstruction performance. Experiments on the fastMRI multi-coil knee dataset demonstrate competitive reconstruction quality compared with existing population- and scan-adaptive sampling approaches at $4\times$ and $8\times$ acceleration factors. In addition, the proposed method enables efficient scan-specific mask prediction with inference cost independent of the training dictionary size.

eess.IV

LaminoDiff: Generative Computed Laminography via Near-Isotropic Spectral Supervision and Anisotropic Geometry

Computed Laminography (CL) is widely used for nondestructive inspection of extended planar objects, but its restricted angular coverage produces an anisotropic point spread function, missing-cone spectral incompleteness, and severe aliasing with interlayer leakage. This paper presents LaminoDiff, a physics-constrained diffusion framework for CL reconstruction. During training, a CT-derived near-isotropic supervision target is reconstructed from full-angle Computed Tomography (CT) projections physically degraded to match CL detector noise and focal-spot blur while retaining full angular coverage; it is withheld from inference. At inference, the reverse process uses only the CL observation. An Anisotropic Representation (AR) constructs depth-aware channels from three adjacent slices: a neighbor average, a center-neighbor residual, and the retained current slice, followed by directional in-plane feature extraction. Experiments on simulated and real multilayer printed circuit board data, including ball grid array and high-frequency stub samples, show that LaminoDiff improves artifact suppression, edge preservation, and depth stratification over analytic Feldkamp--Davis--Kress and representative learning-based baselines.

eess.IV

IViT: A Novel Interpretable Visual Transformer for Skin Disease Detection

The clinical diagnosis of skin diseases is susceptible to interference from inter-class similarity of skin lesions, and over-reliance on clinicians'experience easily leads to subjective bias. Although existing deep learning aided diagnosis methods achieve competitive accuracy, they suffer from the black-box opacity of Vision Transformer (ViT) and poor adaptability to medical few-shot scenarios. Moreover, mainstream explainable algorithms generally face the bottleneck of significant accuracy degradation when improving interpretability. This paper proposes an interpretable ViT (IViT) constrained by Quadratic Programming (QP). The introduced pre-trained transfer learning adapts to few-shot feature extraction. A discrete QP feature selection framework is constructed to screen generic and discriminative features consistent with clinical diagnostic logic. A multi-objective loss function is designed to reduce feature redundancy and optimize activation distribution while preserving classification performance. Experimental results on six standard skin disease datasets show that IViT achieves an accuracy of 93.80%, only 0.21% lower than the baseline, with feature redundancy reduced by 29.5%. Its core activation regions are consistent with clinically concerned lesion areas. The proposed model balances accuracy and interpretability, providing a reliable solution for the clinical deployment of few-shot intelligent skin disease diagnosis.

eess.IV