Search arXivSearch

arXiv · 2506.10916

Semi-Automated Quality Assurance in Digital Pathology: Tile Classification Approach

Abstract

Quality assurance is a critical but underexplored area in digital pathology, where even minor artifacts can have significant effects. Artifacts have been shown to negatively impact the performance of AI diagnostic models. In current practice, trained staff manually review digitized images prior to release of these slides to pathologists which are then used to render a diagnosis. Conventional image processing approaches, provide a foundation for detecting artifacts on digital pathology slides. However, current tools do not leverage deep learning, which has the potential to improve detection accuracy and scalability. Despite these advancements, methods for quality assurance in digital pathology remain limited, presenting a gap for innovation. We propose an AI algorithm designed to screen digital pathology slides by analyzing tiles and categorizing them into one of 10 predefined artifact types or as background. This algorithm identifies and localizes artifacts, creating a map that highlights regions of interest. By directing human operators to specific tiles affected by artifacts, the algorithm minimizes the time and effort required to manually review entire slides for quality issues. From internal archives and The Cancer Genome Atlas, 133 whole slide images were selected and 10 artifacts were annotated using an internally developed software ZAPP (Mayo Clinic, Jacksonville, FL). Ablation study of multiple models at different tile sizes and magnification was performed. InceptionResNet was selected. Single artifact models were trained and tested, followed by a limited multiple instance model with artifacts that performed well together (chatter, fold, and pen). From the results of this study we suggest a hybrid design for artifact screening composed of both single artifact binary models as well as multiple instance models to optimize detection of each artifact.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Meredith VandeHaar, M. Clinch, I. Yilmaz, M. A. Rahman, Y. Xiao, F. Dogany, H. M. Alazab, A. Nassar, Z. Akkus, B. Dangott. 2025-06-12. Semi-Automated Quality Assurance in Digital Pathology: Tile Classification Approach. https://arxiv.org/abs/2506.10916

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

KELP: K-space-conditioned Estimation of Learned Sampling Patterns for Scan-Adaptive Multi-Coil MRI

Deep learning techniques have gained considerable attention for accelerating MRI acquisition while maintaining image quality. In this work, we present a convolutional neural network (CNN)-based framework for predicting scan-adaptive undersampling patterns directly from low-frequency multi-coil $k$-space data. Unlike approaches that optimize sampling patterns during training or rely on nearest-neighbor search at inference, our method is trained using precomputed scan-adaptive optimized masks as supervised labels and predicts a scan-specific sampling pattern in a single forward pass. The training procedure alternates between optimizing the sampling network and a reconstruction network, allowing the learned masks to adapt to reconstruction performance. Experiments on the fastMRI multi-coil knee dataset demonstrate competitive reconstruction quality compared with existing population- and scan-adaptive sampling approaches at $4\times$ and $8\times$ acceleration factors. In addition, the proposed method enables efficient scan-specific mask prediction with inference cost independent of the training dictionary size.

eess.IV

LaminoDiff: Generative Computed Laminography via Near-Isotropic Spectral Supervision and Anisotropic Geometry

Computed Laminography (CL) is widely used for nondestructive inspection of extended planar objects, but its restricted angular coverage produces an anisotropic point spread function, missing-cone spectral incompleteness, and severe aliasing with interlayer leakage. This paper presents LaminoDiff, a physics-constrained diffusion framework for CL reconstruction. During training, a CT-derived near-isotropic supervision target is reconstructed from full-angle Computed Tomography (CT) projections physically degraded to match CL detector noise and focal-spot blur while retaining full angular coverage; it is withheld from inference. At inference, the reverse process uses only the CL observation. An Anisotropic Representation (AR) constructs depth-aware channels from three adjacent slices: a neighbor average, a center-neighbor residual, and the retained current slice, followed by directional in-plane feature extraction. Experiments on simulated and real multilayer printed circuit board data, including ball grid array and high-frequency stub samples, show that LaminoDiff improves artifact suppression, edge preservation, and depth stratification over analytic Feldkamp--Davis--Kress and representative learning-based baselines.

eess.IV

IViT: A Novel Interpretable Visual Transformer for Skin Disease Detection

The clinical diagnosis of skin diseases is susceptible to interference from inter-class similarity of skin lesions, and over-reliance on clinicians'experience easily leads to subjective bias. Although existing deep learning aided diagnosis methods achieve competitive accuracy, they suffer from the black-box opacity of Vision Transformer (ViT) and poor adaptability to medical few-shot scenarios. Moreover, mainstream explainable algorithms generally face the bottleneck of significant accuracy degradation when improving interpretability. This paper proposes an interpretable ViT (IViT) constrained by Quadratic Programming (QP). The introduced pre-trained transfer learning adapts to few-shot feature extraction. A discrete QP feature selection framework is constructed to screen generic and discriminative features consistent with clinical diagnostic logic. A multi-objective loss function is designed to reduce feature redundancy and optimize activation distribution while preserving classification performance. Experimental results on six standard skin disease datasets show that IViT achieves an accuracy of 93.80%, only 0.21% lower than the baseline, with feature redundancy reduced by 29.5%. Its core activation regions are consistent with clinically concerned lesion areas. The proposed model balances accuracy and interpretability, providing a reliable solution for the clinical deployment of few-shot intelligent skin disease diagnosis.

eess.IV