Search arXivSearch

arXiv · 2506.11689

Dark Matter Detector Radioimpurities $^{129}$I and $^{210}$Pb Measured with Accelerator Mass Spectrometry

Abstract

Sodium iodide crystals doped with thallium NaI(Tl) can be used as detector material for direct dark matter detection by taking advantage of their particle detection properties of scintillation. In order to achieve this, it is crucial that these crystals are of ultra-high purity. Radioimpurities within the crystals may potentially mimic dark matter signals and thus must be quantified, minimised where possible and distinguished from real events. Abundances of radionuclides $^{129}$I and $^{210}$Pb, which are dominant sources of radioimpurities in NaI(Tl) crystals, were measured using accelerator mass spectrometry at the Australian National University (ANU) and the Australian Nuclear Science and Technology Organisation (ANSTO). NaI powder chemically processed to AgI, and, for the first time, unprocessed NaI powder, were shown to be suitable as AMS targets. A consistent $^{129}$I/$^{127}$I ratio of (2.0 $\pm$ 0.3) x 10$^{-13}$ was measured in three different commercially available NaI powders. Therefore, it was concluded that the choice of NaI powder has a negligible influence on the $^{129}$I contribution to low-background dark matter experiments. For $^{210}$Pb, different Pb molecular ion species were assessed with PbO$_2^-$ being the preferred species and applied to investigate different lead oxide compounds for their suitability as Pb carriers. A $^{210}$Pb/Pb isotopic ratio of (3.6 $\pm$ $^{1.7}_{1.4}$) x 10$^{-15}$ was measured in Pb$_3$O$_4$ powder. This met the required lower activity limit of $^{210}$Pb when adding 1 mg of stable lead into 1 kg of NaI(Tl) powder with a desired maximum $^{210}$Pb/Pb isotopic ratio of 1 x 10$^{-14}$. These results indicate the suitability of the investigated Pb$_3$O$_4$ as a potential carrier for incorporation with Pb extracted from NaI used for dark matter experiments.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Zuzana Slavkovská, Ferdos Dastgiri, L. Keith Fifield, Michaela B. Froehlich, Michael A. C. Hotchkis, Dominik Koll, Silke Merchel, Stefan Pavetich, Stephen G. Tims, Anton Wallner. 2025-06-13. Dark Matter Detector Radioimpurities $^{129}$I and $^{210}$Pb Measured with Accelerator Mass Spectrometry. https://arxiv.org/abs/2506.11689

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det