Search arXivSearch

arXiv · 2506.12268

Correcting impedance measurements for background parasitics to characterize circuit components in cryogenic environments

Abstract

Predictable circuit response is a critical prerequisite for accurate electronic measurements. We describe a powerful, yet straightforward, experimental method and analysis model that utilizes an affordable LCR meter in conjunction with an in situ parasitic impedance background correction procedure to measure the temperature-dependent impedance (magnitude and phase) of individual passive circuit elements mounted in a cryostat. We show how the model unambiguously identified a 20x drop in capacitance for 22 microF 5XR multilayer ceramic capacitors cooled from 300 K to 360 mK in an environment with parasitic capacitance of order 300 pF. The same experimental procedure, based on a simple two-wire measurement, was also used to successfully measure 10 pF and 22 pF thin-film capacitors and 100 MOhm thick-film resistors. The results showed that the resistor values increased by up to an order of magnitude when the devices were cooled from 300 K to 360 mK. Most importantly, the simple data acquisition method and robust analysis model were shown to effectively extend the accuracy of a simple benchtop LCR meter beyond its manufacturer-guaranteed values for a wide range of measurement frequencies.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Riley J. Carpenter, Jadyn Anczarski, Ivar Rydstrom, Aviv Simchony, Zoe J. Smith, Noah A. Kurinsky, Betty A. Young. 2025-06-13. Correcting impedance measurements for background parasitics to characterize circuit components in cryogenic environments. https://arxiv.org/abs/2506.12268

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det