Search arXivSearch

arXiv · 2506.12628

Two-Mode Bosonic State Tomography with Single-Shot Joint-Parity Measurement of a Trapped Ion

Abstract

The full characterization of a continuous-variable quantum system is a challenging problem. For the trapped-ion system, a number of methods of measuring the quantum states have been developed, including the measurement of the Q quasiprobability function and the density-matrix elements in the Fock basis, but these approaches are often slow and difficult to scale to multimode states. Here, we demonstrate a novel and powerful scheme for measuring a continuous-variable quantum state that uses the direct single-shot measurement of the joint parity of the phonon states of a trapped ion. We drive a spin-dependent bichromatic beam-splitter interaction that coherently exchanges phonons between different harmonic oscillator modes of the ion. This interaction encodes the joint-parity information into the relative phase between the two spin states, enabling measurement of the combined phonon-number parity across multiple modes in a single shot. Leveraging this capability, we directly measure multimode Wigner quasiprobability distributions to perform quantum state tomography of an entangled coherent state, and calculate various quantum informational quantities with a model-based estimation of the density matrix. We further show that the single-shot joint-parity measurement can be used to detect parity-flip errors in real time. By postselecting the parity-measurement outcomes, we experimentally demonstrate the partial recovery of coherence, effectively implementing an error-mitigation technique. Lastly, we identify the various sources of error affecting the fidelity of the spin-dependent beam-splitter operation and study the feasibility of high-fidelity operations. The interaction studied in this work can be extended to more than two modes, and is highly relevant to continuous-variable quantum computing and quantum metrology.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Honggi Jeon, Jiyong Kang, Wonhyeong Choi, Kyunghye Kim, Jaehun You, Taehyun Kim. 2025-12-05. Two-Mode Bosonic State Tomography with Single-Shot Joint-Parity Measurement of a Trapped Ion. https://doi.org/10.1103/wsqr-j9f4

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Iteratively decoded magic state distillation

We present numerical simulation results for the 7-to-1 and 15-to-1 state distillation circuits, constructed using transversal CNOTs acting on multiple surface code patches. The distillation circuits are decoded iteratively using the method outlined in [arXiv:2407.20976]. We show that, with a re-configurable qubit architecture, we can perform fast magic state distillation in $\sim\mathcal{O}(1)$ code cycles. We confirm that both circuits suppress an injected input logical error rate $p$ to $\mathcal{O}(p^3)$ in the presence of additional circuit-level noise. This is done with two types of stabiliser proxies, distilling logical $|-\rangle$ and $|Y\rangle$ states, the latter is the intended state of the 7-to-1 circuit while a stabiliser-proxy for the 15-to-1 circuit. We then also provide numerical evidences for actual $|T\rangle$ state distillation using the 15-to-1 circuit with a faulty-$T$ measurement, leveraging recent near-Clifford simulation tools. Finally, we outline how ZX-calculus and Pauli webs can be used to benchmark stabiliser proxies for these distillation circuits.

quant-ph

Enhanced measurements on quantum computers via the simultaneous probing of non-commuting Pauli operators

Measuring the state of quantum computers is a highly non-trivial task, with implications for virtually all quantum algorithms. A promising avenue is multi-copy schemes, where identical copies of a quantum state are measured jointly so that all Pauli operators within the considered observable can be simultaneously assessed. Here, we present a first implementation of such a two-copy scheme in a measurement protocol. Based on Bayesian statistics, it accurately estimates not only the average of the desired observable but also the error en route. This enables an adaptive shot-allocation algorithm that preferentially samples the most uncertain Pauli terms. In regimes with many non-commuting Pauli operators, this ``double'' scheme can outperform the state-of-the-art measurement protocol in minimizing total shots for a given precision. We also numerically confirm the finding in previous theoretical works that the two-copy scheme incurs an overhead due to the square-root relationship between the variance of measured quantities and the number of measurement shots.

quant-ph

Thermodynamics of a phaseonium-driven optomechanical Otto engine

We study an optomechanical Otto engine whose working medium is a single-mode cavity driven by beams of coherently prepared three-level phaseonium atoms. The atoms are not thermal reservoirs in the Gibbs sense; rather, their populations and ground-state coherence set the detailed-balance ratio of the cavity collision map, so that the field relaxes to a Gibbs state at an operational apparent temperature. We combine the finite-time collision-model dynamics with radiation-pressure work extraction and compare three reservoir preparations: a thermal reference at the same apparent temperatures, an incoherent atomic beam with the same populations, and the coherent phaseonium beam. We show that the phaseonium isochore charges the cavity passively: the cavity ergotropy and energy-basis coherence remain zero up to numerical precision, while the state converges to the Gibbs fixed point selected by the apparent detailed balance. We further estimate lower bounds on the cost of preparing the atomic populations and coherence, showing that the relevant advantage of phaseonium is a resource-preparation tradeoff rather than a cost-free enhancement over a thermal bath at the same temperature. Finally, we assess the finite-time performance of a two-cavity cascade with additive mechanical work accounting. Over the investigated coherence-phase range, the cascade produces approximately $47\%$--$52\%$ more power than the single-cavity engine while requiring only $65\%$--$68\%$ of the hot and cold phaseonium atoms needed by two independent engines, resulting in a $9\%$--$15\%$ enhancement of power per injected atom over a complete cycle.

quant-ph