Search arXivSearch

arXiv · 2506.20206

Volumetric segmentation of muscle compartments using in vivo imaging and architectural validation in human finger flexors

Abstract

Segmenting muscle compartments and measuring their architecture can facilitate movement function assessment, accurate musculoskeletal modeling, and synergy-based electromyogram simulation. Here, we presented a novel method for volumetric segmentation of muscle compartments using in vivo imaging, focusing on the independent compartments for finger control of flexor digitorum superficialis (FDS). Besides, we measured the architectural properties of FDS compartments and validated the segmentation. Specifically, ultrasound and magnetic resonance imaging (MRI) from 10 healthy subjects were used for segmentation and measurement, while electromyography was utilized for validation. A two-step piecewise segmentation was proposed, first annotating compartment regions in the cross-sectional ultrasound image based on compartment movement, and then performing minimum energy matching to register the ultrasound data to the three-dimensional MRI coordinate system. Additionally, the architectural properties were measured in the compartment masks from the segmentation using MRI tractography. Anatomical correctness was verified by comparing known anatomy with reconstructed fiber tracts and measured properties, while segmentation accuracy was quantified as the percentage of finger electromyogram centers falling within their corresponding compartments. Results demonstrated agreement for the fiber orientation between the tractography and cadaveric photographs. Significant differences in architectural properties (P < 0.001) were observed between compartments. The properties of FDS and its compartments were within the physiological ranges (P < 0.01). 95% (38/40) of the electromyogram centers were located within respective compartments, with 2 errors occurring in the index and little fingers. The validated segmentation method and derived architectural properties may advance biomedical applications.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Yang Li. 2025-07-01. Volumetric segmentation of muscle compartments using in vivo imaging and architectural validation in human finger flexors. https://arxiv.org/abs/2506.20206

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

KELP: K-space-conditioned Estimation of Learned Sampling Patterns for Scan-Adaptive Multi-Coil MRI

Deep learning techniques have gained considerable attention for accelerating MRI acquisition while maintaining image quality. In this work, we present a convolutional neural network (CNN)-based framework for predicting scan-adaptive undersampling patterns directly from low-frequency multi-coil $k$-space data. Unlike approaches that optimize sampling patterns during training or rely on nearest-neighbor search at inference, our method is trained using precomputed scan-adaptive optimized masks as supervised labels and predicts a scan-specific sampling pattern in a single forward pass. The training procedure alternates between optimizing the sampling network and a reconstruction network, allowing the learned masks to adapt to reconstruction performance. Experiments on the fastMRI multi-coil knee dataset demonstrate competitive reconstruction quality compared with existing population- and scan-adaptive sampling approaches at $4\times$ and $8\times$ acceleration factors. In addition, the proposed method enables efficient scan-specific mask prediction with inference cost independent of the training dictionary size.

eess.IV

LaminoDiff: Generative Computed Laminography via Near-Isotropic Spectral Supervision and Anisotropic Geometry

Computed Laminography (CL) is widely used for nondestructive inspection of extended planar objects, but its restricted angular coverage produces an anisotropic point spread function, missing-cone spectral incompleteness, and severe aliasing with interlayer leakage. This paper presents LaminoDiff, a physics-constrained diffusion framework for CL reconstruction. During training, a CT-derived near-isotropic supervision target is reconstructed from full-angle Computed Tomography (CT) projections physically degraded to match CL detector noise and focal-spot blur while retaining full angular coverage; it is withheld from inference. At inference, the reverse process uses only the CL observation. An Anisotropic Representation (AR) constructs depth-aware channels from three adjacent slices: a neighbor average, a center-neighbor residual, and the retained current slice, followed by directional in-plane feature extraction. Experiments on simulated and real multilayer printed circuit board data, including ball grid array and high-frequency stub samples, show that LaminoDiff improves artifact suppression, edge preservation, and depth stratification over analytic Feldkamp--Davis--Kress and representative learning-based baselines.

eess.IV

IViT: A Novel Interpretable Visual Transformer for Skin Disease Detection

The clinical diagnosis of skin diseases is susceptible to interference from inter-class similarity of skin lesions, and over-reliance on clinicians'experience easily leads to subjective bias. Although existing deep learning aided diagnosis methods achieve competitive accuracy, they suffer from the black-box opacity of Vision Transformer (ViT) and poor adaptability to medical few-shot scenarios. Moreover, mainstream explainable algorithms generally face the bottleneck of significant accuracy degradation when improving interpretability. This paper proposes an interpretable ViT (IViT) constrained by Quadratic Programming (QP). The introduced pre-trained transfer learning adapts to few-shot feature extraction. A discrete QP feature selection framework is constructed to screen generic and discriminative features consistent with clinical diagnostic logic. A multi-objective loss function is designed to reduce feature redundancy and optimize activation distribution while preserving classification performance. Experimental results on six standard skin disease datasets show that IViT achieves an accuracy of 93.80%, only 0.21% lower than the baseline, with feature redundancy reduced by 29.5%. Its core activation regions are consistent with clinically concerned lesion areas. The proposed model balances accuracy and interpretability, providing a reliable solution for the clinical deployment of few-shot intelligent skin disease diagnosis.

eess.IV