Search arXivSearch

arXiv · 2506.21798

Adaptive Multipath-Based SLAM for Distributed MIMO Systems

Abstract

Localizing users and mapping the environment using radio signals is a key task in emerging applications such as low-latency communications and safety-critical navigation. Recently introduced multipath-based SLAM methods can jointly localize a mobile agent and map reflective surfaces in radio frequency (RF) environments. Most existing methods assume that map features and their corresponding RF propagation paths are statistically independent. This assumption neglects inherent dependencies that arise when a single reflective surface contributes to multiple propagation paths or when an agent communicates with multiple base stations. Existing approaches that aim to fuse information across propagation paths are further limited by their inability to perform ray tracing in RF environments with nonconvex geometries. In this paper, we propose a Bayesian multipath-based SLAM method for distributed MIMO systems that addresses these limitations. We exploit amplitude statistics to establish adaptive, time-varying detection probabilities. Based on the resulting 'soft' ray-tracing strategy, the proposed method can fuse information across propagation paths in RF environments with nonconvex geometries. A Bayesian estimation framework for the joint estimation of map features and agent state is developed by applying the message passing rules of the sum-product algorithm to a factor graph representation of the proposed statistical model. We further introduce a new initialization procedure for reflective surfaces that enables the introduction of new surface states even when measurements arise solely from double-bounce paths. The proposed method is validated using both synthetic and real RF measurements obtained in challenging scenarios with nonconvex geometries and OLoS conditions. The results demonstrate that it provides accurate localization and mapping performance and approaches the posterior CRLBs.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Xuhong Li, Benjamin J. B. Deutschmann, Erik Leitinger, Florian Meyer. 2026-03-27. Adaptive Multipath-Based SLAM for Distributed MIMO Systems. https://arxiv.org/abs/2506.21798

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Subspace Learning with Interval-Censored Likelihoods for Dequantizing Percept PC LFP Snapshots

Implanted neurostimulators that sense local field potentials now enable chronic electrophysiology based biomarker tracking in patients at home. The Medtronic Percept PC, the only commercially available sensing-enabled deep brain stimulation (DBS) device, stores spectral amplitudes as 16-bit integers at approximately 0.1 $μ$V per bit (quantum $q \approx 0.11$ $μ$Vp). At frequencies where the true amplitude spans only a few quantization levels, consecutive bins round to the same stored value. Standard spectral parameterization (FOOOF, fitting oscillations and one over f), which separates periodic peaks from the aperiodic 1/f activity, treats every value as exact and fits oscillatory peaks to these plateaus. Because these spectra feed clinical biomarker pipelines and spectral foundation models for symptom decoding, spurious peaks can corrupt downstream inference. Across 9,438 spectra from 14 hemispheres in 7 subcallosal cingulate DBS patients, 20.6% of peaks detected at [2, 45] Hz have no match in ground truth synthesized by quantizing clean in-clinic BrainSense recordings, while aggregate beta band power and the aperiodic exponent are preserved. We formalize dequantization as interval-censored subspace estimation and compare five classes of correction methods. Quantized probabilistic PCA is the only tested method that reduces the spurious rate (20.6% to 18.3%) while preserving true peak detection and keeping noise floor RMSE below $q/\sqrt{12}$.

eess.SP

TiamiTwin: A Digital Twin for Bistatic ISAC Drone Sensing, Validated Against Measurements

Monitoring lower airspace over critical infrastructure using cellular signals of opportunity is highly practical because transmitters are pre-deployed, licensed, and continuously active. Digital twins can evaluate the feasibility of such integrated sensing and communication (ISAC) architectures, but their predictive accuracy must be validated against real-world data. This paper reports validation results for TiamiTwin, a digital twin developed for bistatic ISAC drone sensing, using empirical measurements from an operational 5G deployment featuring a commercial band n41 gNB and a receiver separated by 572.8 m over a non-line-of-sight (NLOS) channel. TiamiTwin incorporates three parallel channel representations evaluated on a 240-subcarrier grid: the 3GPP TR 38.901 (Release 19) bistatic ISAC model, a ray-traced site model, and the captured field measurements. Empirical results demonstrate that both statistical and ray-tracing models under-predict the measured root-mean-square (RMS) delay spread by approximately a factor of three. Furthermore, target reflections sit 68 dB below static clutter in power, making target detection entirely dependent on Doppler separation to isolate the drone from zero-Doppler background returns. Despite this severe clutter environment, the target remains separable along 88% of the flight path in the delay, Doppler, or joint delay-Doppler domains.

eess.SP

Extracting Physiological Numeric Values from French Pediatric ICU Notes: A Multi-Objective Representation Learning Approach

Numeric values in clinical narratives, such as heart rate, oxygen saturation, and pressure gradients, carry diagnostic meaning that Transformer models trained on generic text do not capture. Objective: We categorize numerical values in French pediatric intensive care unit (PICU) notes into eight physiological categories using CamemBERT-bio, under two constraints that make large-scale LLMs impractical: only 1,072 real, annotated clinical samples are available for this rare, single-site condition, and training must run on GPUs shared concurrently with other hospital workloads rather than a dedicated cluster. Methods: We compare fine-tuning CamemBERT-bio with Label Embedding for Self-Attention (LESA) against combining LESA with Xval, a magnitude-aware number embedding, under a multi-objective training loss. Results: Standard fine-tuning did not improve F1 score, but CamemBERT-bio + LESA raised it by over 13%, and adding Xval matched this gain while approaching GPT-4's performance. Conclusion: LESA and Xval let a compact encoder achieve reliable physiological value extraction under limited real data and shared hospital compute, offering a practical alternative to large-scale LLMs. Significance: Under limited-data and shared-compute constraints, this compact BERT-based language model remains effective without the resource trade-offs of trillion-parameter LLMs.

eess.SP