Search arXivSearch

arXiv · 2507.03790

Upscaling the hyperpolarization sample volume of an automated hydrogenative parahydrogen-induced polarizer

Abstract

Nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI) suffer from inherently low sensitivity due to the weak thermal polarization of nuclear spins. Parahydrogen-induced polarization (PHIP) offers a powerful route to enhance NMR signals by several orders of magnitude, enabling real-time metabolic imaging. However, PHIP implementations are often constrained by small sample volumes, limited automation, and complex high-pressure requirements. In this work, we present an upgraded, automated PHIP system capable of hyperpolarizing sample volumes of up to 2.2 mL, making it suitable for preclinical MRI applications. We developed several high-pressure reactors and multi-port NMR tube caps compatible with standard commercial 5, 10, and 16 mm glass tubes. Reactor designs were simulated and fabricated from chemically resistant polymers, ensuring mechanical safety at more than 30 bar. Using FLASH MRI, nutation, and CPMG sequences, we characterized magnetic field homogeneity and stability, establishing optimal sample dimensions (12.5/16 mm ID/OD glass tube, 20 mm height) with B0 inhomogeneity below 2.5 ppm and B1 inhomogeneity around 1%. A high level of injection reproducibility was confirmed (volume precision ~0.6%). Optimization of experimental parameters, including hydrogenation pressure, pH2 flow rate, and sample temperature, enabled rapid and efficient polarization transfer. At optimized conditions (20 bar pH2, 2 L/min flow, 55°C, 4 s bubbling time), up to 31.3% 1H polarization of two protons was achieved for deuterated ethyl acetate in acetone with the theoretical maximum of 50%. This level of polarization was achieved with a duty cycle of 80 s, and the standard deviation of the mean was below 6.8%.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Yenal Gökpek, Jan-Bernd Hövener, Andrey N. Pravdivtsev. 2025-07-08. Upscaling the hyperpolarization sample volume of an automated hydrogenative parahydrogen-induced polarizer. https://doi.org/10.1021/acsmeasuresciau.5c00097

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det