Evaluation of a Full Field Fluorescence Imager with Synchrotron Radiation

Abstract

The design and evaluation on the NSLS-II beamline of the 3FI application specific integrated circuit (ASIC) bump-bonded to a simply, planar, two-dimensionally segmented silicon sensor is presented. The ASIC was developed for Full-Field Fluorescence spectral X-ray Imaging (3FI). It is a small-scale prototype that features a square array of 32x32 pixels with a pitch of 100 μm. The ASIC was implemented in a 65 nm CMOS process. Each pixel incorporates a charge-sensitive amplifier, shaping filter, discriminator, peak detector, and sample-and-hold circuit, allowing detection of events and storing signal amplitudes. The system operates in an event-driven readout mode, outputting analog values for threshold-triggered events, allowing high-speed multi-element X-ray fluorescence imaging. At power consumption of 200 μW per pixel, consisting almost uniquely of power dissipated in analog blocks, 308 eV full width at half maximum (FWHM) energy resolution at 8.04 keV, that corresponds to 30 e- rms equivalent noise charge (ENC) and 138 eV FWHM energy resolution at 3.69 keV (16 e- rms ENC) were obtained, for Cu and Ca Kα lines, respectively. Each pixel operates independently, and the detector enables in situ trace element microanalysis in biological and environmental research. Its architecture addresses limitations of X-ray Fluorescence Microscopy (XFM), typically requiring mechanical scanning, by offering frame-lees data acquisition, translating to high-throughput operation. The 3FI ASIC is suitable for example for studies of nutrient cycling in the (mycor)rhizosphere, microbial redox processes, and genotype-phenotype correlations in bio-energy crops. Additional performances, such as enhanced spatial resolution can be further improved with coded-aperture and Wolt, extending the use to environmental, biomedical, and material science studies.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Piotr Maj, Grzegorz W. Deptuch, Dominik S. Gorni, Giovanni Pinaroli, Gabriella A. Carini, David P. Siddons, Ryan Tappero, Soumyajit Mandal, Donald Pinelli, Timothy Kersten, Nicholas St. John, Abdul K. Rumaiz, Anthony Kuczewski. 2025-08-01. Evaluation of a Full Field Fluorescence Imager with Synchrotron Radiation. https://arxiv.org/abs/2507.14425

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det