Search arXivSearch

arXiv · 2507.19958

Crystal Eye: all sky MeV monitor with high precision real-time localization

Abstract

Crystal Eye is a space-based all-sky monitor optimized for the autonomous detection and localization of transients in the 10 keV to 30 MeV energy range, a region where extensive observations and monitoring of various astrophysical phenomena are required. By focusing on the operating environment and its impact on the observation process, we optimized the detector design and assessed its scientific potential. We explored the use of novel techniques to achieve the science goals of the experiment. We assumed the orbit of a potential future mission at approximately 550 km altitude near the equatorial region with a 20° inclination. In such an orbit, the main background contributions for this kind of detector are from different particles and radiation of cosmic origin and secondaries produced by their interaction in the Earth's atmospheric and geomagnetic environment. We studied the response of the detector in this background environment, using the Geant4 Monte Carlo simulation toolkit. We also calculated other detector performance parameters to estimate its scientific capabilities. The detector effective area and efficiency are calculated for low energy gamma-ray sources and used to estimate its sensitivity to short-duration transient sources. The calculation shows a better effective area and sensitivity by several factors compared to existing instruments of similar type. A method is also developed and discussed to estimate the online transient-localization performance of the detector, suggesting a better localization precision by about an order of magnitude than those typically reported by existing gamma-ray monitors. We present here the simulation study and results of an innovative detector design concept that can make a significant contribution in the multi-messenger era. Moreover, this study can be useful as a technical reference for similar future experiments.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Roberto Aloisio, Uygar Atalay, Biswajit Banerjee, Felicia C. T. Barbato, Elisabetta Bissaldi, Marica Branchesi, Fiamma Capitanio, Elisabetta Casilli, Roberta Colalillo, Ivan De Mitri, Alessio De Santis, Adriano Di Giovanni, Mateo Fernandez Alonso, Giulio Fontanella, Fabio Gargano, Fabio Garufi, Fausto Guarino, Dimitrios Kyratzis, Herman Lima, Francesco Loparco, Francesco Longo, Riccardo Martinelli, Teresa Montaruli, Gor Oganesyan, Javier Rico, Filippo Santoliquido, Ritabrata Sarkar, Pierpaolo Savina, Iqra Siddique, Aleksei Smirnov, Matteo Tambone, Antonella Tarana, Andrii Tykhonov, Laura Valore, A. A. Vigliano, Libo Wu. 2025-09-08. Crystal Eye: all sky MeV monitor with high precision real-time localization. https://doi.org/10.1016/j.astropartphys.2025.103171

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Performance characterization of a new Structural and Thermal Architecture for a future spaceborne Closed-Cycle Dilution Refrigerator

A Structural and Thermal Model (STM) has been developed to support the new spaceborne Closed-Cycle Dilution Refrigerator (CCDR), which aims to provide continuous cooling at 100~mK for long-duration astrophysical missions. The STM is based on a hexapod architecture that ensures both thermal decoupling and mechanical robustness during launch. In this paper, we present the characterization of its thermal and mechanical performances. A dedicated experimental setup was used to investigate the thermal behavior of the STM across a broad temperature range. The study reveals limitations of the collar design, with incomplete power interception from thermal boundary resistances and vibration test failure traced to defective strut gluing. These results guide the next STM iteration with optimized collar and strut assembly for reliable CCDR operation in space.

astro-ph.IM

The Simons Observatory: Development of a Pipeline to Detect Rapid Transients in Time-Ordered Data

We introduce a method for detecting astrophysical transients evolving on timescales of milliseconds to minutes using cosmic microwave background (CMB) survey telescopes. While previous transient searches in CMB data operate in map space, our pipeline directly processes the raw time-ordered data, enabling sensitivity to fast, dynamic signals. We integrate our detection approach into the Simons Observatory time-domain pipeline and assess the performance by injecting symmetric, stellar flare-like light curves into simulated observations. For events flaring with a timescale of 0.5 s, the pipeline detects $\gtrsim90$ % of events at flux densities of 800, 1150, 1650, and 4250\,mJy when measured in the 93, 145, 225, and 280 GHz bands respectively. At a fixed peak flux density, the pipeline more readily detects longer flares. The limiting flux density for 90 % completeness is four times lower for a $\ge5$ s flare than for a 0.5 s flare, while the flux density limits for $\gtrsim50$ % detection efficiency are comparable to the rms noise of the time-ordered data. We are able to determine the position of detected events in each observing band, with a positional uncertainty at the detection threshold comparable to the telescope resolution at that band. These results demonstrate the readiness of this pipeline for incorporation into upcoming Simons Observatory data analyses.

astro-ph.IM

Thermal conductivity of various CFRPs from 100 mK to 20 K

Carbon-fiber-reinforced polymers (CFRPs) are some of the most useful materials for building spacecraft and aerospace tools. They are especially valuable for systems that work at extremely cold (cryogenic) temperatures because they are strong, lightweight, and don't transfer heat easily. In this study, researchers measured how well heat moves through several different types of carbon fiber samples, specifically T300, T700, HS40, M55J, and IMA, at different fiber layouts and densities. These measurements were taken at ultra-cold temperatures ranging from 100 mK to 20 K. The team used a newly developed analysis method to calculate the thermal conductivity for each sample. Finally, they shared how each material behaved at different temperatures and compared their findings to previous research.

astro-ph.IM