Search arXivSearch

arXiv · 2507.21853

Comparison of diffuse correlation spectroscopy analytical models for cerebral blood flow measurements

Abstract

Multi-layer diffuse correlation spectroscopy (DCS) models have been developed to reduce the contamination of superficial signals in cerebral blood flow index (CBFi) measurements. However, a systematic comparison of these models and clear guidance on model selection are still lacking. This study compares three DCS analytical models: semi-infinite, two-layer, and three-layer, focusing on their fitting strategies, performance, and suitability for CBFi and relative CBFi (rCBFi) estimation. We simulated DCS data using a four-layer slab head model with the Monte Carlo eXtreme (MCX) toolkit. Multiple fitting strategies were evaluated: early time lag range (ETLR) fitting with fixed or variable beta for the semi-infinite model, and single-distance (SD) and multi-distance (MD) fitting for the two- and three-layer models. Model performance was assessed based on CBFi sensitivity, accuracy of CBFi and rCBFi recovery, resistance to signal contamination from scalp and skull, sensitivity to assumed parameter errors, and computational efficiency across source-detector separations of 20 to 35 mm. Optimal fitting methods include ETLR with fixed beta for the semi-infinite model, SD with fixed beta for the two-layer model, and MD for the three-layer model. The multi-layer models achieved higher CBFi sensitivity (up to 100%) compared to 36.8% for the semi-infinite model. The two-layer model offered the best balance of accuracy and robustness, while the three-layer model enabled simultaneous recovery of CBFi, scalp BFi, and rCBFi. The semi-infinite model was the most computationally efficient, requiring only 0.38 seconds for 500 samples, supporting its use in real-time monitoring. This work offers a practical and systematic evaluation of DCS analytical models and provides guidance for selecting the most appropriate model based on application needs.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Mingliang Pan, Quan Wang, Yuanzhe Zhang, David Day-Uei Li. 2025-07-29. Comparison of diffuse correlation spectroscopy analytical models for cerebral blood flow measurements. https://arxiv.org/abs/2507.21853

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Prediction of biological radiation effects based on ionization clusters (nanodosimetry)

This article reviews approaches that link the formation of ionization clusters in nanometric volumes to radiobiological effectiveness. The corresponding models were developed as the field of nanodosimetry developed. Some address early biological radiation effects, such as DNA damage, while most aim to predict cell survival or inactivation. The models also differ in the nanodosimetric quantities considered, with many based on the probability distribution of ionization cluster formation in a single target. Some models account for the synergistic effects of pairs of ionization clusters formed in different targets. Several models feature macroscopic aggregation frameworks based on particle fluence, which are proposed for use in radiotherapy treatment planning, particularly in ion-beam radiotherapy. The models are presented here using harmonized terminology and notation for nanodosimetric quantities. An extension of the conceptual framework of nanodosimetry is also discussed. This extension transitions from a target-centered description to a track-centered description. It also introduces nanodosimetry-based analogs of dosimetric concepts, such as dose and linear energy transfer. This paper traces and summarizes the historical development of nanodosimetry-based biological effect models and discusses conceptual aspects of the models to reveal their underlying assumptions and the extent to which they are mechanistic or merely elucidate correlations. Eventually, an attempt is made to identify the key open questions in this field that still need to be addressed.

physics.med-ph

Contextual Cellular Growth (ConCeG) of neural cells for realistic grey matter tissue generation for diffusion MRI simulations

Accurate interpretation of diffusion magnetic resonance imaging (dMRI) signals in grey matter (GM) remains challenging due to the complex, heterogeneous, and densely packed cellular environment. Numerical phantoms provide a controlled framework for investigating the relationship between microstructure and diffusion signals, yet existing approaches often lack the morphological realism and multi-cellular organisation required to faithfully represent GM tissue. In this work, we introduce Contextual Cellular Growth (ConCeG), a generative framework for creating individual cells or constructing dense, three-dimensional, multi-cellular GM substrates informed by real neuronal and glial morphologies. The method combines topological neuron synthesis with a spatially constrained growth network, allowing for the controlled generation of heterogeneous cellular environments with realistic intra- and extracellular compartments. Synthetic cells are generated using morphological and topological characteristics derived from biological reconstructions. We validate the framework through comparisons of structural features with real cellular data, demonstrating strong agreement in branch order, length, angle, and tortuosity distributions. Power spectrum analysis further shows that both intracellular compartments reproduce the spatial correlations observed in biological tissue. Together, these results show ConCeG provides a biologically grounded framework for generating grey matter substrates suitable for large scale diffusion MRI simulation.

physics.med-ph

Magnetic Field of Firing Neuron in Humans: Measurable by Quantum Sensing MRI?

Firing neurons generate action potentials that propagate along axons to transmit signals supporting cognitive functions. These electrical currents generate magnetic fields, yet direct detection of these neuronal magnetic fields by MRI remains elusive. This Mini Review investigates why this goal has been proven difficult to achieve and whether an emerging approach, quantum sensing MRI, can overcome the challenge.

physics.med-ph