Search arXivSearch

arXiv · 2508.02169

A Dual Radiomic and Dosiomic Filtering Technique for Locoregional Radiation Pneumonitis Prediction in Breast Cancer Patients

Abstract

Purpose: Radiation pneumonitis (RP) is a serious complication of intensity-modulated radiation therapy (IMRT) for breast cancer patients, underscoring the need for precise and explainable predictive models. This study presents an Explainable Dual-Omics Filtering (EDOF) model that integrates spatially localized dosiomic and radiomic features for voxel-level RP prediction. Methods: A retrospective cohort of 72 breast cancer patients treated with IMRT was analyzed, including 28 who developed RP. The EDOF model consists of two components: (1) dosiomic filtering, which extracts local dose intensity and spatial distribution features from planning dose maps, and (2) radiomic filtering, which captures texture-based features from pre-treatment CT scans. These features are jointly analyzed using the Explainable Boosting Machine (EBM), a transparent machine learning model that enables feature-specific risk evaluation. Model performance was assessed using five-fold cross-validation, reporting area under the curve (AUC), sensitivity, and specificity. Feature importance was quantified by mean absolute scores, and Partial Dependence Plots (PDPs) were used to visualize nonlinear relationships between RP risk and dual-omic features. Results: The EDOF model achieved strong predictive performance (AUC = 0.95 +- 0.01; sensitivity = 0.81 +- 0.05). The most influential features included dosiomic Intensity Mean, dosiomic Intensity Mean Absolute Deviation, and radiomic SRLGLE. PDPs revealed that RP risk increases beyond 5 Gy and rises sharply between 10-30 Gy, consistent with clinical dose thresholds. SRLGLE also captured structural heterogeneity linked to RP in specific lung regions. Conclusion: The EDOF framework enables spatially resolved, explainable RP prediction and may support personalized radiation planning to mitigate pulmonary toxicity.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Zhenyu Yang, Qian Chen, Rihui Zhang, Manju Liu, Fengqiu Guo, Minjie Yang, Min Tang, Lina Zhou, Chunhao Wang, Minbin Chen, Fang-Fang Yin. 2025-08-04. A Dual Radiomic and Dosiomic Filtering Technique for Locoregional Radiation Pneumonitis Prediction in Breast Cancer Patients. https://arxiv.org/abs/2508.02169

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Prediction of biological radiation effects based on ionization clusters (nanodosimetry)

This article reviews approaches that link the formation of ionization clusters in nanometric volumes to radiobiological effectiveness. The corresponding models were developed as the field of nanodosimetry developed. Some address early biological radiation effects, such as DNA damage, while most aim to predict cell survival or inactivation. The models also differ in the nanodosimetric quantities considered, with many based on the probability distribution of ionization cluster formation in a single target. Some models account for the synergistic effects of pairs of ionization clusters formed in different targets. Several models feature macroscopic aggregation frameworks based on particle fluence, which are proposed for use in radiotherapy treatment planning, particularly in ion-beam radiotherapy. The models are presented here using harmonized terminology and notation for nanodosimetric quantities. An extension of the conceptual framework of nanodosimetry is also discussed. This extension transitions from a target-centered description to a track-centered description. It also introduces nanodosimetry-based analogs of dosimetric concepts, such as dose and linear energy transfer. This paper traces and summarizes the historical development of nanodosimetry-based biological effect models and discusses conceptual aspects of the models to reveal their underlying assumptions and the extent to which they are mechanistic or merely elucidate correlations. Eventually, an attempt is made to identify the key open questions in this field that still need to be addressed.

physics.med-ph

Contextual Cellular Growth (ConCeG) of neural cells for realistic grey matter tissue generation for diffusion MRI simulations

Accurate interpretation of diffusion magnetic resonance imaging (dMRI) signals in grey matter (GM) remains challenging due to the complex, heterogeneous, and densely packed cellular environment. Numerical phantoms provide a controlled framework for investigating the relationship between microstructure and diffusion signals, yet existing approaches often lack the morphological realism and multi-cellular organisation required to faithfully represent GM tissue. In this work, we introduce Contextual Cellular Growth (ConCeG), a generative framework for creating individual cells or constructing dense, three-dimensional, multi-cellular GM substrates informed by real neuronal and glial morphologies. The method combines topological neuron synthesis with a spatially constrained growth network, allowing for the controlled generation of heterogeneous cellular environments with realistic intra- and extracellular compartments. Synthetic cells are generated using morphological and topological characteristics derived from biological reconstructions. We validate the framework through comparisons of structural features with real cellular data, demonstrating strong agreement in branch order, length, angle, and tortuosity distributions. Power spectrum analysis further shows that both intracellular compartments reproduce the spatial correlations observed in biological tissue. Together, these results show ConCeG provides a biologically grounded framework for generating grey matter substrates suitable for large scale diffusion MRI simulation.

physics.med-ph

Magnetic Field of Firing Neuron in Humans: Measurable by Quantum Sensing MRI?

Firing neurons generate action potentials that propagate along axons to transmit signals supporting cognitive functions. These electrical currents generate magnetic fields, yet direct detection of these neuronal magnetic fields by MRI remains elusive. This Mini Review investigates why this goal has been proven difficult to achieve and whether an emerging approach, quantum sensing MRI, can overcome the challenge.

physics.med-ph