Search arXivSearch

arXiv · 2508.06527

Half-life Measurements of Highly Charged Radioisotopes by Nuclear Recoil in a Penning Trap

Abstract

We present a novel method for measuring the half-life of highly charged radioisotopes by non-destructive nuclear recoil detection in a Penning ion trap. A specific emphasis is placed on $\rm ^7Be^{3+}$, which plays a crucial role in stellar evolution and the production of solar neutrinos. The determination of the half-life is necessary to constrain the free electron capture rate in the solar environment, but is difficult to measure by existing techniques. Simulations of the sympathetic cooling of the recoiled daughter nuclei ($\rm ^7Li^{3+}$) with the trapped cloud of $\rm ^7Be^{3+}$ demonstrate a decay detection efficiency of $99.5\%$. A statistical analysis of half-life measurements on ensembles containing hundreds of ions shows that a final statistical uncertainty of less than $5\%$ is achieved with only 500 measured decays. By coherent control of hyperfine populations in trapped ions, the fidelity of the technique we describe enables the direct measurement and manipulation of state-dependent decay branching ratios for the first time.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Scott Moroch, Carolyn Chun, Doug VanDerwerken, Ariana Shearin, Brian Beaudoin, Klaus Blaum, Timothy Koeth. 2025-08-02. Half-life Measurements of Highly Charged Radioisotopes by Nuclear Recoil in a Penning Trap. https://arxiv.org/abs/2508.06527

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det