Search arXivSearch

arXiv · 2508.10172

In-orbit Spectral Calibration Prospects for the COSI Space Telescope

Abstract

The Compton Spectrometer and Imager is an upcoming NASA space telescope in the MeV range. COSI's primary science goals include precisely mapping nuclear line and positron annihilation emission in the Milky Way galaxy through Compton imaging. This relies on our ability to maintain COSI's spectral performance over its mission lifetime. Changes to the detectors' gain characteristics over time will result in a non-linear stretching of the entire energy range. Moreover, observations from past MeV telescopes and proton-beam experiments have shown that radiation damage in space causes photopeak shifts and spectral line broadening. These necessitate a plan for regular, in-orbit calibration. In this study, we demonstrate a method to monitor and recalibrate the COSI detectors using background line emissions produced by the space radiation environment. We employ Monte Carlo simulations of particle background and show that strong background lines arise from nuclear excitation of COSI's detectors (germanium) and cryostat (aluminum) materials. These span COSI's entire bandwidth for single-site interactions and can be used to monitor the effects of radiation damage and gain shifts every eight hours at the full instrument level and every 24 days at the individual detector level. Methods developed by Pike et al. to correct the effects of hole trapping and gain characteristics can then be applied to recover the original spectral performance. These results inform COSI's telemetry requirements for calibration and housekeeping data, and rule out the need for an on-board radioactive calibration source which would have increased the complexity of the spacecraft.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Aravind B. Valluvan, Steven E. Boggs, Savitri Gallego, Jarred Roberts, Gabriel Brewster, Sophia Haight, Carolyn Kierans, Sean Pike, Albert Y. Shih, John A. Tomsick, Andreas Zogaluer. 2026-01-08. In-orbit Spectral Calibration Prospects for the COSI Space Telescope. https://arxiv.org/abs/2508.10172

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Performance characterization of a new Structural and Thermal Architecture for a future spaceborne Closed-Cycle Dilution Refrigerator

A Structural and Thermal Model (STM) has been developed to support the new spaceborne Closed-Cycle Dilution Refrigerator (CCDR), which aims to provide continuous cooling at 100~mK for long-duration astrophysical missions. The STM is based on a hexapod architecture that ensures both thermal decoupling and mechanical robustness during launch. In this paper, we present the characterization of its thermal and mechanical performances. A dedicated experimental setup was used to investigate the thermal behavior of the STM across a broad temperature range. The study reveals limitations of the collar design, with incomplete power interception from thermal boundary resistances and vibration test failure traced to defective strut gluing. These results guide the next STM iteration with optimized collar and strut assembly for reliable CCDR operation in space.

astro-ph.IM

The Simons Observatory: Development of a Pipeline to Detect Rapid Transients in Time-Ordered Data

We introduce a method for detecting astrophysical transients evolving on timescales of milliseconds to minutes using cosmic microwave background (CMB) survey telescopes. While previous transient searches in CMB data operate in map space, our pipeline directly processes the raw time-ordered data, enabling sensitivity to fast, dynamic signals. We integrate our detection approach into the Simons Observatory time-domain pipeline and assess the performance by injecting symmetric, stellar flare-like light curves into simulated observations. For events flaring with a timescale of 0.5 s, the pipeline detects $\gtrsim90$ % of events at flux densities of 800, 1150, 1650, and 4250\,mJy when measured in the 93, 145, 225, and 280 GHz bands respectively. At a fixed peak flux density, the pipeline more readily detects longer flares. The limiting flux density for 90 % completeness is four times lower for a $\ge5$ s flare than for a 0.5 s flare, while the flux density limits for $\gtrsim50$ % detection efficiency are comparable to the rms noise of the time-ordered data. We are able to determine the position of detected events in each observing band, with a positional uncertainty at the detection threshold comparable to the telescope resolution at that band. These results demonstrate the readiness of this pipeline for incorporation into upcoming Simons Observatory data analyses.

astro-ph.IM

Thermal conductivity of various CFRPs from 100 mK to 20 K

Carbon-fiber-reinforced polymers (CFRPs) are some of the most useful materials for building spacecraft and aerospace tools. They are especially valuable for systems that work at extremely cold (cryogenic) temperatures because they are strong, lightweight, and don't transfer heat easily. In this study, researchers measured how well heat moves through several different types of carbon fiber samples, specifically T300, T700, HS40, M55J, and IMA, at different fiber layouts and densities. These measurements were taken at ultra-cold temperatures ranging from 100 mK to 20 K. The team used a newly developed analysis method to calculate the thermal conductivity for each sample. Finally, they shared how each material behaved at different temperatures and compared their findings to previous research.

astro-ph.IM