Search arXivSearch

arXiv · 2508.12115

Scalable and robust wide-field facet calibration with LOFAR's longest baselines

Abstract

Recent work has successfully achieved sub-arcsecond wide-field imaging with high-band observations from the Low Frequency Array (LOFAR). However, the scalability of this work remains limited due to the need for manual intervention, poor calibration solutions for the Dutch LOFAR stations, and high computational costs. We address these issues by: (1) improving automated self-calibration using a signal-to-noise metric and a neural network for image artefact detection; (2) implementing a refined calibration strategy for the Dutch LOFAR stations; and (3) cutting computational costs by optimising the data processing strategy. We demonstrate the effectiveness of our automated processing strategy by reprocessing one previously reduced dataset and a new dataset from the ELAIS-N1 deep field, which features more severe ionospheric conditions. We find calibration artefacts across facet boundaries to be reduced with our improved automated calibration strategy and achieve a computational cost reduction of about a factor of 4 to 6 compared to previous work, where the exact factor depends on whether a single observation is processed or multiple observations of the same sky area are combined. Further optimisation and improved handling of data with baseline-dependent averaging could reduce this in the near future by another factor of two, bringing the total cost for an 8-hour observation below 30,000 CPU core hours. This work enables ultra-deep imaging at sensitivities on the order of a few $μ$Jy/beam. Furthermore, it also lays the foundation for a fully automated survey pipeline for sub-arcsecond wide-field imaging of the northern sky with LOFAR.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J. M. G. H. J. de Jong, L. Veefkind, R. J. van Weeren, J. B. R. Oonk, R. J. Schlimbach, D. N. G. Kampert, M. van der Wild, L. K. Morabito, F. Sweijen, A. R. Offringa, H. J. A. Röttgering. 2025-08-16. Scalable and robust wide-field facet calibration with LOFAR's longest baselines. https://arxiv.org/abs/2508.12115

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Performance characterization of a new Structural and Thermal Architecture for a future spaceborne Closed-Cycle Dilution Refrigerator

A Structural and Thermal Model (STM) has been developed to support the new spaceborne Closed-Cycle Dilution Refrigerator (CCDR), which aims to provide continuous cooling at 100~mK for long-duration astrophysical missions. The STM is based on a hexapod architecture that ensures both thermal decoupling and mechanical robustness during launch. In this paper, we present the characterization of its thermal and mechanical performances. A dedicated experimental setup was used to investigate the thermal behavior of the STM across a broad temperature range. The study reveals limitations of the collar design, with incomplete power interception from thermal boundary resistances and vibration test failure traced to defective strut gluing. These results guide the next STM iteration with optimized collar and strut assembly for reliable CCDR operation in space.

astro-ph.IM

The Simons Observatory: Development of a Pipeline to Detect Rapid Transients in Time-Ordered Data

We introduce a method for detecting astrophysical transients evolving on timescales of milliseconds to minutes using cosmic microwave background (CMB) survey telescopes. While previous transient searches in CMB data operate in map space, our pipeline directly processes the raw time-ordered data, enabling sensitivity to fast, dynamic signals. We integrate our detection approach into the Simons Observatory time-domain pipeline and assess the performance by injecting symmetric, stellar flare-like light curves into simulated observations. For events flaring with a timescale of 0.5 s, the pipeline detects $\gtrsim90$ % of events at flux densities of 800, 1150, 1650, and 4250\,mJy when measured in the 93, 145, 225, and 280 GHz bands respectively. At a fixed peak flux density, the pipeline more readily detects longer flares. The limiting flux density for 90 % completeness is four times lower for a $\ge5$ s flare than for a 0.5 s flare, while the flux density limits for $\gtrsim50$ % detection efficiency are comparable to the rms noise of the time-ordered data. We are able to determine the position of detected events in each observing band, with a positional uncertainty at the detection threshold comparable to the telescope resolution at that band. These results demonstrate the readiness of this pipeline for incorporation into upcoming Simons Observatory data analyses.

astro-ph.IM

Thermal conductivity of various CFRPs from 100 mK to 20 K

Carbon-fiber-reinforced polymers (CFRPs) are some of the most useful materials for building spacecraft and aerospace tools. They are especially valuable for systems that work at extremely cold (cryogenic) temperatures because they are strong, lightweight, and don't transfer heat easily. In this study, researchers measured how well heat moves through several different types of carbon fiber samples, specifically T300, T700, HS40, M55J, and IMA, at different fiber layouts and densities. These measurements were taken at ultra-cold temperatures ranging from 100 mK to 20 K. The team used a newly developed analysis method to calculate the thermal conductivity for each sample. Finally, they shared how each material behaved at different temperatures and compared their findings to previous research.

astro-ph.IM