Accuracy of propagation-based phase-contrast CT under the projection approximation

Abstract

X-ray phase-contrast imaging has the potential to improve image contrast with lower dose by probing an object's refractive properties as well as its absorptive properties. To reconstruct a phase-contrast image from a raw dataset, a phase retrieval algorithm must be applied to invert the forward model of the image acquisition scheme. Discrete forward modeling presents unique computational challenges due to high x-ray wave field sampling requirements. At the cost of accuracy, approximations are often applied for the sake of simplicity and experimental convenience. One of the most ubiquitous simplifications is the projection approximation, which neglects refractive effects within an object. The approximation's validity decreases when imaging thicker objects or using a detector with higher spatial resolution. For greater accuracy, one might use the multislice model instead. In this work, we explore the accuracy of the projection approximation in simulated synchrotron micro-CT images. We simulated images using two detector resolutions (0.5 and 2 micron) with either the projection approximation or multislice forward model. Paganin phase retrieval was applied to the resulting datasets, and the final phase-contrast images were reconstructed using filtered back-projection. The 2-micron resolution detector images showed little difference between forward models, indicating the projection approximation is satisfied. With sub-micron resolution, there is a noticeable difference in the phase-contrast images, especially around fine details. An accurate phase retrieval algorithm for such high-resolution data likely requires more detailed forward modeling that avoids making the projection approximation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Giavanna Jadick, Patrick La Rivière. 2025-08-17. Accuracy of propagation-based phase-contrast CT under the projection approximation. https://arxiv.org/abs/2508.12505

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Prediction of biological radiation effects based on ionization clusters (nanodosimetry)

This article reviews approaches that link the formation of ionization clusters in nanometric volumes to radiobiological effectiveness. The corresponding models were developed as the field of nanodosimetry developed. Some address early biological radiation effects, such as DNA damage, while most aim to predict cell survival or inactivation. The models also differ in the nanodosimetric quantities considered, with many based on the probability distribution of ionization cluster formation in a single target. Some models account for the synergistic effects of pairs of ionization clusters formed in different targets. Several models feature macroscopic aggregation frameworks based on particle fluence, which are proposed for use in radiotherapy treatment planning, particularly in ion-beam radiotherapy. The models are presented here using harmonized terminology and notation for nanodosimetric quantities. An extension of the conceptual framework of nanodosimetry is also discussed. This extension transitions from a target-centered description to a track-centered description. It also introduces nanodosimetry-based analogs of dosimetric concepts, such as dose and linear energy transfer. This paper traces and summarizes the historical development of nanodosimetry-based biological effect models and discusses conceptual aspects of the models to reveal their underlying assumptions and the extent to which they are mechanistic or merely elucidate correlations. Eventually, an attempt is made to identify the key open questions in this field that still need to be addressed.

physics.med-ph

Contextual Cellular Growth (ConCeG) of neural cells for realistic grey matter tissue generation for diffusion MRI simulations

Accurate interpretation of diffusion magnetic resonance imaging (dMRI) signals in grey matter (GM) remains challenging due to the complex, heterogeneous, and densely packed cellular environment. Numerical phantoms provide a controlled framework for investigating the relationship between microstructure and diffusion signals, yet existing approaches often lack the morphological realism and multi-cellular organisation required to faithfully represent GM tissue. In this work, we introduce Contextual Cellular Growth (ConCeG), a generative framework for creating individual cells or constructing dense, three-dimensional, multi-cellular GM substrates informed by real neuronal and glial morphologies. The method combines topological neuron synthesis with a spatially constrained growth network, allowing for the controlled generation of heterogeneous cellular environments with realistic intra- and extracellular compartments. Synthetic cells are generated using morphological and topological characteristics derived from biological reconstructions. We validate the framework through comparisons of structural features with real cellular data, demonstrating strong agreement in branch order, length, angle, and tortuosity distributions. Power spectrum analysis further shows that both intracellular compartments reproduce the spatial correlations observed in biological tissue. Together, these results show ConCeG provides a biologically grounded framework for generating grey matter substrates suitable for large scale diffusion MRI simulation.

physics.med-ph

Magnetic Field of Firing Neuron in Humans: Measurable by Quantum Sensing MRI?

Firing neurons generate action potentials that propagate along axons to transmit signals supporting cognitive functions. These electrical currents generate magnetic fields, yet direct detection of these neuronal magnetic fields by MRI remains elusive. This Mini Review investigates why this goal has been proven difficult to achieve and whether an emerging approach, quantum sensing MRI, can overcome the challenge.

physics.med-ph